Total output pulses to be generated are invalid or communications channel is shut down, causing a controller fault. The manual's first action is: “Reconfigure the channel and retry operation.”
- Model
- Rockwell Automation MicroLogix 1400
- Display shows
- Length Error (7)
- Type
- Error code
- Source
- Manual p. 106
What 7 means
Length Error p. 258
Common causes
- The total output pulses to be generated (TOP) are less than zero. This error faults the controller. It can be cleared by logic within the User Fault Routine. p. 258
- The instruction cannot be executed because the communications channel has been shut down via the channel configuration menu. p. 258
- Socket error during Receive operation p. 258
- The file number does not exist. p. 258
What to do
- Reconfigure the channel and retry operation. p. 258
Before you service the product, read the safety instructions in the manual p. 274.
If 7 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Rockwell Automation service.
This page summarises what the manufacturer’s manual says about 7; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Rockwell Automation. Found a mistake? Report an error.