Analog Devices ADE7755 Manuals

ManualLib has 5 documents for the Analog Devices ADE7755: 5 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 5

Key facts

Model
ADE7755
Industry
Industrial
Documents
5
Languages
EN
Last added
2012-08-02

Start here

DatasheetANALOG DEVICES ADE7755: Energy Metering IC with Pulse Output Data Sheet (Rev A 2009-08-07-)

ANALOG DEVICES ADE7755: Energy Metering IC with Pulse Output Data Sheet (Rev A 2009-08-07-)

Datasheet

ADE7755 is a power metering IC produced by Analog Devices. It has high accuracy, high dynamic range and multiple output functions. It is widely used in power metering, electric vehicle charging and other fields.

Read online

Analog Devices ADE7755 specifications

Measurement Error (Gain=1)0.1% Reading typ
Phase Error (PF=0.8 Capacitive)+/-0.1 Degrees max
Reference Temperature Coefficient30 ppm/°C typ
Supply Voltage Range4.75 V min to 5.25 V max
Package Type24-Lead SSOP

Source: Analog Devices ADE7755 Energy Metering IC Datasheet

All Analog Devices ADE7755 documents by type

Questions answered in these manuals

What is the accuracy of the ADE7755?

The measurement error is less than 0.1% reading typical over a dynamic range of 500 to 1.

From: Analog Devices ADE7755 Energy Metering IC Datasheet

What are the frequency outputs used for?

Outputs F1 and F2 supply average real power, while output CF supplies instantaneous real power intended for calibration.

From: Analog Devices ADE7755 Energy Metering IC Datasheet

What supply voltage range is required for the ADE7755?

The device operates from 4.75 V min to 5.25 V max, which is 5 V ± 5 %.

From: Analog Devices ADE7755 Energy Metering IC Datasheet

How many pins does the ADE7755 have and what package is it offered in?

It is offered in a 24‑lead SSOP package with pins numbered 1‑24 as shown in the pin configuration table.

From: Analog Devices ADE7755 Energy Metering IC Datasheet

What is the allowed supply voltage range for AVpp?

AVpp must be between 4.75 V minimum and 5.25 V maximum, which corresponds to 5 V ± 5 %.

From: Analog Devices ADE7755 Energy Metering IC Datasheet

What is the nominal on‑chip reference voltage?

The on‑chip reference is nominally 2.5 V with a tolerance of ±8 %.

From: Analog Devices ADE7755 Energy Metering IC Datasheet