Key facts
- Brand
- Analog Devices
- Model
- ADE7754
- Industry
- Industrial
- Documents
- 5
- Languages
- EN
- Last added
- 2012-08-02
Start here

Analog Devices ADE7754 Datasheet
The ADE7754 is a high accuracy polyphase electrical energy measurement IC designed for measuring active and apparent energy. It supports various power meter services including 3-phase/4-wire, 3-phase/3-wire, and 4-wire delta configurations. The device incorporates second order X-A ADCs, reference circuitry, and a temperature sensor to perform active, apparent energy measurements, and RMS calculations.
Read onlineAnalog Devices ADE7754 specifications
| Active Power Measurement Error | 0.1 % typ |
|---|---|
| Supply Voltage | 5 V + 5% |
| Input Clock Frequency | 10 MHz typ |
| Package Type | 24-lead SOIC |
| On-Chip Temperature Sensor | +4 °C |
Source: Analog Devices ADE7754 Datasheet
All Analog Devices ADE7754 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
How to use the product for one specific task, with worked examples.
Questions answered in these manuals
What is the typical active power measurement error?
The typical active power measurement error is 0.1% over a dynamic range of 1000 to 1.
What is the supply voltage range for the ADE7754?
The device operates with a single 5 V supply, with a minimum of 4.75 V and a maximum of 5.25 V.
What services can a 3-phase energy meter interface with?
The meter can interface with 3-phase 4-wire, 3-phase 3-wire, and 3-phase 4-wire with 2% elements services.
What calculations can the meter provide?
The meter provides active, reactive, and apparent energy calculations as well as power quality measurements, voltage rms, and current rms.
What is the maximum analog input range of the ADE7754?
The maximum analog input range is 500mV with a PGA of 1, 2, or 4 on all channels.
From: Analog Devices ADE7754 Multi-functional Polyphase Energy Metering IC Datasheet
Does the ADE7754 support temperature sensing?
Yes, it includes a temperature sensor with a maximum error of +/-0.5 degrees.
From: Analog Devices ADE7754 Multi-functional Polyphase Energy Metering IC Datasheet