Analog Devices ADE7752 Manuals

ManualLib has 5 documents for the Analog Devices ADE7752: 4 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 4

Key facts

Model
ADE7752
Industry
Industrial
Documents
5
Languages
EN
Last added
2012-08-02

Start here

ANALOG DEVICES AN-641 handbook

ANALOG DEVICES AN-641 handbook

Application Note 16 pages · 496 KB · EN

The document details a reference design for a Class 1 meter intended for use in Wye-connected 3-phase, 4-wire distribution systems. It meets IEC 61036 and Indian Standards IS 13779-99 accuracy requirements, achieving less than 0.1% error over a 500:1 current dynamic range for balanced loads.

The design utilizes the ADE7752 single-chip solution which includes analog-to-digital converters and digital signal processing. Key features include differential output drivers for electromechanical counters, high-frequency pulse outputs for calibration, and logic outputs to indicate negative active power or miswiring.

Read online

Analog Devices ADE7752 specifications

Accuracy ClassClass 1
Current Dynamic Range500:1
Maximum Current per Phase50 A
Meter Constant100 impulses/kWh
Line Voltage to Neutral240 V
Startup Current13.75 mA
No-Load Threshold3.3 W

Source: ANALOG DEVICES AN-641 handbook

All Analog Devices ADE7752 documents by type

Application Note 1

How to use the product for one specific task, with worked examples.

Questions answered in these manuals

What accuracy class does this meter design meet?

The design meets the IEC 61036 Class 1 meter accuracy requirement.

From: ANALOG DEVICES AN-641 handbook

What is the maximum current per phase for this design?

The meter was designed for a maximum current of 50 A per phase.

From: ANALOG DEVICES AN-641 handbook

What is the difference between ADE7752 and ADE7752A?

The ADE7752A is a pin-to-pin compatible low power version of the ADE7752.

From: Analog Devices ADE7752/ADE7752A Polyphase Energy Metering IC Datasheet

What configurations does this IC support?

It supports 3-phase/3-wire delta and 3-phase/4-wire wye configurations.

From: Analog Devices ADE7752/ADE7752A Polyphase Energy Metering IC Datasheet

What is the error performance of the ADE7752?

It surpasses IEC1036 Class 1 meter requirements with less than 0.1% error over a wide current dynamic range.

From: Analog Devices ADE7752 Three-Phase Energy Metering IC Datasheet

What types of three-phase connections is the ADE7752 suitable for?

It supports direct connect, transformer operated, three-wire service, and four-wire service connections.

From: Analog Devices ADE7752 Three-Phase Energy Metering IC Datasheet