Agilent 7700x Manuals

ManualLib has 9 documents for the Agilent 7700x: 1 product leaflet, 7 application notes. Every file can be read online or downloaded as a PDF for free.

Product Leaflet 1Application Note 7

Key facts

Brand
Agilent
Model
7700x
Documents
9
Languages
JA · EN
Last added
2012-07-06

Start here

Agilent 7700x ICP-MS Drinking Water Analysis Superiority Brochure

Agilent 7700x ICP-MS Drinking Water Analysis Superiority Brochure

Product Leaflet 6 pages · 281 KB · JA

The Agilent 7700x ICP-MS features a third-generation Octapole Reaction System (ORS3) that significantly improves the performance of the helium (He) collision mode. This allows for the removal of polyatomic ion interferences without the need for sample-specific knowledge or complex interference correction equations, simplifying method creation and reducing analysis time. This manual is written in Japanese.

Read online

Agilent 7700x specifications

Forward RF power1550 W
Carrier gas flow0.56 L/min
Dilution gas flow0.33 L/min
Sample loop volume600 uL
Online dilution factor1:2

Source: Agilent 7700x ICP-MS Application Note for FGD Wastewater Analysis

All Agilent 7700x documents by type

Questions answered in these manuals

What detection limit does the Agilent 7700x ICP-MS achieve for selenium in He mode?

The instrument can consistently achieve a detection limit of less than 20 ppt for selenium.

From: Agilent 7700x ICP-MS Drinking Water Analysis Superiority Brochure

How long does it take to analyze a sequence of 190 samples including calibration checks?

The system completes a sequence of 190 analyses in 11 hours.

From: Agilent 7700x ICP-MS Drinking Water Analysis Superiority Brochure

What is the detection limit for tributyl tin (TBT)?

The analysis achieved a detection limit of 5.9 ppt for tributyl tin.

From: Agilent 7700x ICP-MS GC Interface Application Note

What is the detection limit for tributyl tin (TBT) in the organo-tin analysis?

The analysis achieved a detection limit of 5.9 ppt for tributyl tin (TBT).

From: Agilent 7700x ICP-MS GC Interface Application Note

Does the 7700x ICP-MS require reactive cell gases for drinking water analysis?

No, the 7700x ICP-MS removes all polyatomic interferences under a single set of conditions without requiring reactive cell gases.

From: Agilent 7700x ICP-MS Application Note for Drinking Water Analysis

What is the operating dynamic range of the 7700x ICP-MS?

It has the largest operating dynamic range of any quadrupole ICP-MS.

From: Agilent 7700x ICP-MS Application Note for Drinking Water Analysis