Agilent ProSEC 300S Manuals

ManualLib has 7 documents for the Agilent ProSEC 300S (Other): 1 datasheet, 5 application notes. Every file can be read online or downloaded as a PDF for free.

Datasheet 1Application Note 5

Key facts

Brand
Agilent
Model
ProSEC 300S
Category
Other
Documents
7
Languages
EN
Last added
2012-07-04

Start here

Agilent ProSEC 300S Columns for Protein SEC Data Sheet

Agilent ProSEC 300S Columns for Protein SEC Data Sheet

Datasheet 2 pages · 443 KB · EN

The document details the ProSEC 300S columns, which contain hydrophobic silica particles designed for the separation of biomolecules including proteins and peptides. It covers installation requirements, such as the use of specific stainless steel tubing and compatible connectors to minimize dead volume. The text also specifies that column connections must be made using Parker compatible 1/16 in nuts and ferrules.

Read online

Agilent ProSEC 300S specifications

Typical operating pressure900 psi (60 bar)
Maximum operating pressure3700 psi (250 bar)
Maximum operating temperature40 °C
Efficiency> 75,000 plates

Source: Agilent ProSEC 300S Columns for Protein SEC Data Sheet

All Agilent ProSEC 300S documents by type

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What eluent pH range is recommended for ProSEC 3008 columns?

Buffered eluent systems within the pH range 5.0-7.5 are recommended.

From: Agilent ProSEC 300S Columns for Protein SEC Data Sheet

Can organic solvents be used with ProSEC 3008 columns?

Yes, organic solvents and organic/aqueous mixtures may be used.

From: Agilent ProSEC 300S Columns for Protein SEC Data Sheet

What is the physical size of the ProSEC 3008 column used in this analysis?

The column dimensions are 300 x 7.5 mm.

From: Agilent Analysis of Albumin Proteins using ProSEC 300S Columns Manual

What flow rate was used during the protein analysis?

The sample was analyzed at a flow rate of 1.0 mL/min.

From: Agilent Analysis of Albumin Proteins using ProSEC 300S Columns Manual

What proteins were used for calibration?

The calibration used Thyroglobulin, y-Globulin, Bovine serum albumin, Ovalbumin, Carbonic anhydrase, Myoglobulin, Cytochrome C, and Bacitracin.

From: Agilent ProSEC 300S Columns Calibration Application Note

What does the calibration curve show?

The calibration curve shows a linear relationship between the log of the molecular weight and the retention time.

From: Agilent ProSEC 300S Columns Calibration Application Note