Agilent PL-GPC 50 Plus Poly(styrene-co-butadiene) GPC Application Note
This document details the analysis of styrene/butadiene rubber copolymers using gel permeation chromatography (GPC) with viscometry. It explains that while light scattering is unsuitable for these copolymers due to non-uniform chemistry, the Universal Calibration technique using a viscometer provides accurate molecular weight distributions independent of column standards.
The analysis was performed on an Agilent PL-GPC 50 Plus integrated system equipped with a differential refractive index detector, an Agilent PL-BV AQ0RT viscometer, and PLgel 5 pm MIXED-C columns. The results demonstrate the system's ability to resolve molecular weight distributions and determine material structure for elastomeric materials.
Agilent PL-GPC 50 Plus specifications
| Flow Rate | 1 mL/min |
|---|---|
| Temperature | 40°C |
| Column Dimensions | 300 x 7.5 mm |
| Operating Temperature Range | ambient to 50 °C |
Source: Agilent PL-GPC 50 Plus Poly(styrene-co-butadiene) GPC Application Note
All Agilent PL-GPC 50 Plus documents by type
How to use the product for one specific task, with worked examples.
- Agilent PL-GPC 50 Plus Poly(styrene-co-butadiene) GPC Application Note 3 p
- Agilent PL-GPC 50 Plus Application Note: Analysis of Cornflour by GPC with Viscometry 3 p
- Agilent PL-GPC 50 Plus Aqueous SEC Triple Detection Application Note 3 p
- Agilent PL-GPC 50 Plus Analysis of Polyesters by GPC with Light Scattering Detection Application Note 2 p
- Agilent PL-GPC 50 Plus Analysis of Polylactide Application Note 3 p
- Agilent PL-GPC 50 Poly(styrene/butadiene) Copolymer Analysis Application Note 2 p
- Analysis of Melamine Resins by Conventional GPC using PolarGel-L Columns Application Note 2 p
- Agilent PL-GPC 50 Plus Size Exclusion Chromatography for Dental Polymers Application Note 3 p
- Agilent PL-GPC 50 Plus Starch Analysis Application Note 2 p
- Agilent PL-GPC 50 Plus Analysis of Polyols by GPC with Viscometry Application Note 3 p
Questions answered in these manuals
Why is viscometry used instead of light scattering for these samples?
Light scattering cannot be used because the samples are copolymers with non-uniform chemistry, which leads to errors in calculations.
From: Agilent PL-GPC 50 Plus Poly(styrene-co-butadiene) GPC Application Note
What advantage does the Universal Calibration technique offer?
It gives molecular weight that is independent of the standards used in the column calibration.
From: Agilent PL-GPC 50 Plus Poly(styrene-co-butadiene) GPC Application Note
What instrument was used to analyze the cornflour samples?
The samples were analyzed by an Agilent PL-GPC 50 Plus fitted with an Agilent PL-BV 400RT viscometer.
From: Agilent PL-GPC 50 Plus Application Note: Analysis of Cornflour by GPC with Viscometry
How was the structure of the cornflour samples compared?
The structure was compared using the Mark-Houwink plot of log (intrinsic viscosity) as a function of log (molecular weight).
From: Agilent PL-GPC 50 Plus Application Note: Analysis of Cornflour by GPC with Viscometry
Does the PL-GPC 50 Plus require column calibration for triple detection analysis?
No, using triple detection allows the sample to be analyzed without the need to perform a column calibration.
From: Agilent PL-GPC 50 Plus Aqueous SEC Triple Detection Application Note
What is the operating temperature range of the PL-GPC 50 Plus?
The system is designed for operation from ambient to 50°C.
From: Agilent PL-GPC 50 Plus Aqueous SEC Triple Detection Application Note