Agilent 490-GC Manuals

ManualLib has 8 documents for the Agilent 490-GC: 6 user manuals, 2 datasheets. Every file can be read online or downloaded as a PDF for free.

User Manual 6Datasheet 2

Key facts

Brand
Agilent
Model
490-GC
Industry
Industrial
Documents
8
Languages
EN
Last added
2012-07-04

Start here

Varian 490-GC Sulfur in Gas Analyzer Product Leaflet

Varian 490-GC Sulfur in Gas Analyzer Product Leaflet

Product Leaflet 2 pages · 106 KB · EN

The Varian 490-GC Sulfur in Gas Analyzer is designed for fast and reliable on-line or at-line sulfur analysis of hydrocarbon streams. It features complementary dual-detector technology, combining a universal Thermal Conductivity Detector (u-TCD) with a highly sensitive Differential Mobility Detector (u-DMD). This setup allows the analyzer to obtain data on bulk matrix composition while simultaneously targeting trace levels of specific sulfur components without interference from other co-eluting matrix components.

The instrument is a turnkey solution that comes factory pre-tuned and includes full documentation and an operational method. It utilizes electronic gas control (EGC) for high reproducibility and capillary column technology for efficient separation. Due to its compact size, the analyzer is suitable for both on-line monitoring of odorant levels in operations and laboratory analysis.

Read online

Agilent 490-GC specifications

ApplicabilityDetermination of hydrogen sulfide, carbonyl sulfide and methyl mercaptan in gaseous hydrocarbon streams.
Sample Temperature Range0 °C to 110 °C
Sample PressureAmbient up to 1 bar
Analysis TimeApproximately four minutes
u-TCD Dynamic RangeSix decades
Minimum Detectability u-DMD H2S300 µg/m³ (200 ppb)
Minimum Detectability u-DMD COS500 µg/m³ (200 ppb)
Minimum Detectability u-DMD CH3SH400 µg/m³ (200 ppb)
Repeatability u-DMDBetter than 3% relative standard deviation at 10-20 times the minimum detectability
Hardware ConfigurationSingle channel dual detector configuration based on the 490-GC

Source: Varian 490-GC Sulfur in Gas Analyzer Product Leaflet

All Agilent 490-GC documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Application Note 2

How to use the product for one specific task, with worked examples.

Questions answered in these manuals

What is the primary function of the Varian 490-GC Sulfur in Gas Analyzer?

It measures trace levels of targeted sulfur components in gaseous hydrocarbon streams with no matrix interference.

From: Varian 490-GC Sulfur in Gas Analyzer Product Leaflet

What detectors does the analyzer use?

It features complementary dual-detector technology using a universal Thermal Conductivity Detector (u-TCD) and a Differential Mobility Detector (u-DMD).

From: Varian 490-GC Sulfur in Gas Analyzer Product Leaflet

What gases can the 490-GC analyze?

It analyzes halogenated components such as halothane, enflurane, isoflurane, desflurane, and sevoflurane.

From: Varian 490-GC Anesthetic Gas Analyzer Product Leaflet

Is the analyzer factory pre-tuned?

Yes, it is factory pre-tuned to specifications and supplied with full documentation and an operational method.

From: Varian 490-GC Anesthetic Gas Analyzer Product Leaflet

What components can this analyzer determine in gaseous hydrocarbon streams?

The analyzer determines methyl mercaptan, ethyl mercaptan, iso-propoyl mercaptan, n-propyl mercaptan and TBM.

From: Varian 490-GC Mercaptans in Gas Analyzer Product Leaflet

What is the maximum pressure for the sample offered to this analyzer?

The sample must be offered with a pressure from ambient up to 1 bar.

From: Varian 490-GC Mercaptans in Gas Analyzer Product Leaflet