Agilent 4500 ICP-MS Manuals

ManualLib has 5 documents for the Agilent 4500 ICP-MS: 4 application notes, 1 other. Every file can be read online or downloaded as a PDF for free.

Application Note 4Other 1

Key facts

Brand
Agilent
Model
4500 ICP-MS
Documents
5
Languages
EN
Last added
2012-07-02

Start here

Agilent 4500 ICP-MS Silicon Wafer Surface Metals Characterization Application Note

Agilent 4500 ICP-MS Silicon Wafer Surface Metals Characterization Application Note

Application Note 6 pages · 113 KB · EN

The document details a technique combining Vapor Phase Decomposition (VPD) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) for characterizing trace metal contaminants on silicon wafers. This method allows for sample preparation and analysis in less than 30 minutes, enabling real-time monitoring of wafer production.

Read online

Agilent 4500 ICP-MS specifications

Analysis Timeless than 30 minutes
Detection Limitspart per trillion and sub part per trillion
RF Power930 Watts
Carrier Gas Flow1.0 L/min
Blend Gas Flow0.55 L/min

Source: Agilent 4500 ICP-MS Silicon Wafer Surface Metals Characterization Application Note

All Agilent 4500 ICP-MS documents by type

Questions answered in these manuals

How many elements can be analyzed in a single droplet?

The technique allows for the accurate analysis of up to 40 elements in a single droplet.

From: Agilent 4500 ICP-MS Silicon Wafer Surface Metals Characterization Application Note

How long does it take to prepare and analyze a silicon wafer sample?

Wafer sample preparation and analysis can be performed in less than 20 minutes.

From: Agilent 4500 ICP-MS Silicon Wafer Surface Metals Characterization Application Note

What metals does this method determine in heavy oil?

The method determines vanadium and nickel in heavy oil.

From: Agilent 4500 ICP-MS Application Note for Determining Vanadium and Nickel in Heavy Oil

What is the typical sample uptake rate for the 4500 ICP-MS?

The instrument is typically operated at a sample uptake rate of 0.4 mL/min.

From: Agilent 4500 ICP-MS Application Note for Determining Vanadium and Nickel in Heavy Oil

How long does the sample analysis take including loading?

The sample analysis time, including sample loading, is approximately three minutes.

From: Agilent 4500 ICP-MS with LSX-100 Semiquantitative Analysis Application Note

What is the diameter of the laser crater achieved during analysis?

The resulting crater was approximately 30um in diameter.

From: Agilent 4500 ICP-MS with LSX-100 Semiquantitative Analysis Application Note