Agilent 500-MS Manuals

ManualLib has 14 documents for the Agilent 500-MS: 5 user manuals, 4 application notes, 1 installation guide, 1 datasheet. Every file can be read online or downloaded as a PDF for free.

User Manual 5Application Note 4Installation Guide 1Datasheet 1

Key facts

Brand
Agilent
Model
500-MS
Industry
Industrial
Documents
14
Languages
EN
Last added
2012-07-04

Start here

Agilent 500-MS IT Mass Spectrometer MS Workstation V6 Software Operation Manual

Agilent 500-MS IT Mass Spectrometer MS Workstation V6 Software Operation Manual

User Manual 182 pages · 11 MB · EN

This document serves as an operation manual for the Varian (now Agilent) MS Workstation Version 6.9 software, which controls the 500-MS ion trap mass spectrometer, associated chromatography modules, and the LC Combi PAL AutoSampler. The software manages hardware control, data acquisition, display, reduction, and analysis.

Read online

Agilent 500-MS specifications

Mass range50 to 2000u
Resolution<0.5u FWHM over the entire range
Mass axis stability+ 0.1u over 24 hours at constant temperature
Max ion time500,000 psec
Drying gas temperature (ESI)400°C max
LC flow range (ESI)1 to 1000 pL/min
Needle voltage (ESI)6 kV max
LC flow range (APCI)100 pL/min to 2 mL/min
Auxiliary gas temperature (APCI)550°C max
Power requirements100-120, 200-240 Vac, +10 %, 50/60 Hz, 3200 VA (steady state)
Operating Temperature16°C to 30°C
Weight (MS)135 lb/ 62 kg

Source: Varian 500-MS LC Ion Trap Mass Spectrometer Specifications

All Agilent 500-MS documents by type

User Manual 5

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Installation Guide 1

Mounting, wiring and first power-up. Read it before the hardware goes in.

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the mass range of the Varian 500-MS?

The mass range is from 50 to 2000u.

From: Varian 500-MS LC Ion Trap Mass Spectrometer Specifications

Can the drying gas temperature be programmed?

Yes, SelecTemp allows temperature programming of the drying gas throughout the analysis.

From: Varian 500-MS LC Ion Trap Mass Spectrometer Specifications

What is the mass range of the 500-MS?

The mass range is 50 to 2000u.

From: Agilent 500-MS LC Ion Trap Mass Spectrometer Specifications

What is the resolution of the analyzer?

The resolution is less than 0.5u FWHM over the entire range.

From: Agilent 500-MS LC Ion Trap Mass Spectrometer Specifications

What is the main difference between an ion trap mass spectrometer and a triple quadrupole mass filter?

Ion traps store ions simultaneously within trapping electrodes and eject them sequentially, allowing MS/MS in the same space. Triple quadrupoles use separate filters and collision cells distributed in space.

From: Agilent 500-MS Ion Trap Mass Spectrometer FAQs

What are the strengths of an ion trap mass spectrometer?

They offer fast, sensitive full scan spectra for MS and MS/MS, excellent high mass sensitivity, structural elucidation capabilities via MSn, and a lower price point.

From: Agilent 500-MS Ion Trap Mass Spectrometer FAQs