Analog Devices AD1380 16-Bit Sampling ADC Datasheet
The AD1380 is a complete, low cost 16-bit analog-to-digital converter that includes an internal reference, clock, and sample/hold amplifier. It features parallel output and is designed for applications such as medical instrumentation, signal processing, data acquisition systems, professional audio, automatic test equipment (ATE), telecommunications, and general signal processing.
Read onlineAnalog Devices AD1380 specifications
| Resolution | 16 Bits |
|---|---|
| Throughput | 50 kHz |
| Package Type | 32-lead hermetic DIP |
| Digital Supply Voltage | +5V |
| Operating Temperature Range | -25 to +85 °C |
All Analog Devices AD1380 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the maximum linearity error for the AD1380KD model?
The maximum linearity error is +0.003% of FSR.
Is a serial output function available for this device?
No, the serial output function is no longer available after date code 0120.
What is the maximum sampling rate of the AD1380?
The AD1380 can sample at up to 50 kHz throughput.
How much power does the AD1380 dissipate?
Typical power dissipation is 900 mW.