Analog Devices AD1362 16-Channel Data Acquisition System Datasheet
The AD1362 is a complete, precision 16-channel data acquisition system designed to interface directly with popular analog-to-digital converters. It contains two 8-channel multiplexers, a differential amplifier, a sample-and-hold circuit, and channel address latches. A unique feature is an internal user-controllable analog switch that allows the device to operate in either single-ended or differential mode without external hard-wiring.
Read onlineAnalog Devices AD1362 specifications
| Resolution | 12-Bit Precision |
|---|---|
| Acquisition Time | 10µs to 0.01% |
| Input Impedance (On Channel) | >10 GΩ |
| Common Mode Rejection | 80dB |
Source: Analog Devices AD1362 16-Channel Data Acquisition System Datasheet
All Analog Devices AD1362 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the operating temperature range for the AD1362KD?
The AD1362KD is specified for operation over a 0 to +70°C temperature range.
From: Analog Devices AD1362 16-Channel Data Acquisition System Datasheet
What is the operating temperature range for the AD1362SD?
The AD1362SD operates from -55°C to +125°C.
From: Analog Devices AD1362 16-Channel Data Acquisition System Datasheet
How many channels can the AD1362 handle?
It supports 16 single‑ended channels or 8 differential channels, selectable via the mode control pin.