Start here

Agilent Zorbax SB-C3 Reversed-Phase Column Datasheet
The Agilent Zorbax SB-C3 is a microparticulate column packing designed for reversed-phase high performance liquid chromatography (HPLC). It utilizes a StableBond stationary phase made by chemically bonding a sterically protected isopropyl phase to high-purity Zorbax porous-silica microspheres. This design reduces strong adsorption of basic compounds and offers enhanced chemical stability against aggressive mobile phases, such as those with low pH or high ionic strength.
Read onlineAgilent SB-C3 specifications
| Particle Type | Microparticulate column packing |
|---|---|
| Stationary Phase | Sterically protected isopropyl stationary phase |
| Support Material | High-purity, Zorbax, porous-silica microsphere |
| Pore Size | 80A |
| Maximum Operating Pressure | 400 bar (6000 psi) |
| Maximum Operating Temperature | 80°C |
| Recommended pH Range | pH 1.0 to 8 |
Source: Agilent Zorbax SB-C3 Reversed-Phase Column Datasheet
All Agilent SB-C3 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
Is the Zorbax SB-C3 column compatible with aggressive mobile phases?
Yes, it is particularly well suited for use with aggressive mobile phases such as those with pH <2, high ionic strength, or ion-pair additives due to the steric protection of the bonded phase.
What is the recommended storage solvent for the Zorbax SB-C3 column?
Long term storage should be in a pure organic solvent, preferably an aprotic liquid such as 100% acetonitrile.
What is the maximum operating pressure for the ZORBAX SB-C3 column?
The column supports operation up to 600 bar (9,000 psi).
From: Agilent ZORBAX SB-C3 Rapid Resolution HT Threaded Column Data Sheet
Can the ZORBAX SB-C3 column be used with basic compounds?
Yes, it is well-suited for basic, neutral, or acidic samples due to its special silica support that reduces strong adsorption of basic compounds.
From: Agilent ZORBAX SB-C3 Rapid Resolution HT Threaded Column Data Sheet
What is the effect of changing the bonded-phase type?
Changing the bonded-phase type is useful as a tool to change the selectivity of a separation.
From: Agilent Bonded-Phase Selectivity Separation of Local Anesthetics Application Note
What improvement is noted with ZORBAX columns?
Improved peak shape on ZORBAX results from more desirable silanol interactions.
From: Agilent Bonded-Phase Selectivity Separation of Local Anesthetics Application Note