Agilent SB-C8 Manuals

ManualLib has 4 documents for the Agilent SB-C8: 2 user manuals, 1 datasheet. Every file can be read online or downloaded as a PDF for free.

User Manual 2Datasheet 1

Key facts

Brand
Agilent
Model
SB-C8
Industry
Industrial
Documents
4
Languages
EN
Last added
2012-07-04

Start here

Agilent ZORBAX SB-C8 RRHT Threaded Column Datasheet

Agilent ZORBAX SB-C8 RRHT Threaded Column Datasheet

Datasheet 2 pages · 80 KB · EN

This document describes the Agilent ZORBAX SB-C8 RRHT threaded columns, which are engineered for high-pressure liquid chromatography (HPLC) operations up to 600 bar. The columns utilize StableBond technology, featuring a sterically-protected C8 stationary phase chemically bonded to high-purity ZORBAX porous silica microspheres. This design reduces the adsorption of basic compounds and provides enhanced stability against aggressive mobile phases, including those with low pH or high ionic strength, as well as elevated temperatures up to 80 °C.

Read online

Agilent SB-C8 specifications

Maximum operating pressure600 bar (9000 psi)
Maximum operating temperature80 °C
Particle size1.8 µm
Pore size80 Å
Compatible pH rangepH 1.0 to 8.0

Source: Agilent ZORBAX SB-C8 RRHT Threaded Column Datasheet

All Agilent SB-C8 documents by type

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Application Note 1

How to use the product for one specific task, with worked examples.

Questions answered in these manuals

What is the maximum operating pressure for these columns?

The maximum operating pressure is 600 bar (9000 psi).

From: Agilent ZORBAX SB-C8 RRHT Threaded Column Datasheet

Can these columns be used at high temperatures?

Yes, the columns are stable when operated at temperatures up to 80 °C.

From: Agilent ZORBAX SB-C8 RRHT Threaded Column Datasheet

What is the recommended column size for this separation?

The recommended column size is 4.6 x 75 mm.

From: Agilent ZORBAX SB-C8 Separation of Deoxy Ribonucleosides Application Note

What is the recommended flow rate for this separation?

The recommended flow rate is 2.0 mL/min.

From: Agilent ZORBAX SB-C8 Separation of Deoxy Ribonucleosides Application Note

What is the effect of changing the bonded-phase type?

Changing the bonded-phase type is useful as a tool to change the selectivity of a separation.

From: Agilent Bonded-Phase Selectivity Separation of Local Anesthetics Application Note

What improvement is noted with ZORBAX columns?

Improved peak shape on ZORBAX results from more desirable silanol interactions.

From: Agilent Bonded-Phase Selectivity Separation of Local Anesthetics Application Note