Agilent SD-1 Manuals

ManualLib has 3 documents for the Agilent SD-1: 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Brand
Agilent
Model
SD-1
Industry
Industrial
Documents
3
Languages
EN
Last added
2026-11-14

Start here

Agilent PrepStar SD-1 Preparative HPLC Training Manual

Agilent PrepStar SD-1 Preparative HPLC Training Manual

User Manual 13 pages · 1.2 MB · EN

The Agilent PrepStar SD-1 is a dual-pump preparative HPLC with analytical, semi-prep, and prep modes. It uses three C18 column sizes, two manual injectors with 500 ul and 10 ml sample loops, and requires appropriate guard columns.

The manual covers operating instructions, direct device control, new method setup, data acquisition, and a test-mix standard experiment with operating conditions.

Read online

Agilent SD-1 specifications

Pump configurationDual pump (binary)
Pump capacity3.2 L/min
Maximum pressure375 psi
Analytical column4.6 x 50 mm, 1.8 um
Semi-prep column9.4 x 250 mm, 5 um
Prep column21.2 x 250 mm, 7 um
Flow rates1, 4.2, and 21.0 ml/min
Sample loads2-10, 10-50, and 50-200 mg
Injection volumes1-20 ul, 100-400 ul, 500 ul-5 ml
Analytical/semi-prep injector loop500 ul
Prep injector loop10 ml

Source: Agilent PrepStar SD-1 Preparative HPLC Training Manual

All Agilent SD-1 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

Which manual injector is used for preparative separations?

The bottom injector, which is equipped with a 10 ml sample loop.

From: Agilent PrepStar SD-1 Preparative HPLC Training Manual

What flow rate must be set when no solvent flow is intended?

0.000 ml/min.

From: Agilent PrepStar SD-1 Preparative HPLC Training Manual

What is the maximum flow rate the SD-1 Solvent Delivery Modules can handle?

The exchangeable pump heads support flow rates up to 800 mL/min.

From: Agilent SD-1 Purification System Overview Manual

What is the settable flow rate range for the Agilent SD-1 Purification System?

The system allows a settable flow rate range from 0.01 mL/min up to 800 mL/min.

From: Agilent SD-1 Purification System Overview Manual

What is the maximum pressure capability of the SD-1?

The system supports a high-pressure capability of up to 6,000 psi.

From: Agilent PrepStar SD-1 Solvent Delivery System Product Leaflet

Which software is recommended for process applications?

LC ReSponder software is best suited for process applications.

From: Agilent PrepStar SD-1 Solvent Delivery System Product Leaflet