ANALOG DEVICES ADuC824: Errata Sheet (Rev 1.0 2000-12-01-)

ANALOG DEVICES ADuC824: Errata Sheet (Rev 1.0 2000-12-01-)

Other 2 pages · 13 KB · EN

The Analog Devices ADuC824 is a 16/24-bit ADC with an embedded Flash MCU. This errata sheet details specific issues found in all silicon branded as ADUC824BS, including known bugs and anomalies.

A critical issue identified involves indirect addressing modes where certain Special Function Registers (SFRs) cannot be read correctly using this method. The document provides a workaround involving the use of the accumulator register to bypass these restrictions for specific registers like ADCSTAT.

Read online

Analog Devices ADUC824 specifications

Timeout Interval Range1/128 second to 255 hours
Supported MicroConverter PartsADuC814, ADuC816, ADuC824, ADuC831, ADuC832, ADuC834
Clock Source32.768KHz watch crystal or r/c oscillator
Powerdown CapabilityRemains active during powerdown

Source: Analog Devices MicroConverter Time Interval Counter Application Note

All Analog Devices ADUC824 documents by type

User Manual 3

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Application Note 2

How to use the product for one specific task, with worked examples.

Questions answered in these manuals

What is the revision status of this errata sheet?

This is Revision 1.0, dated December 2000, covering all silicon branded ADUC824BS.

From: ANALOG DEVICES ADuC824: Errata Sheet (Rev 1.0 2000-12-01-)

Which SFRs cannot be read using indirect addressing?

The following SFRs cannot be read using indirect addressing: ADCMODE, ADCOCON, ADCICON, SF, ICON, PSMCON, ADCSTAT, ADCOL/M/H, ADCIL/H, OFOL/M/H, OFIL/H, GNOL/M/H, GNIL/H, DACL/H, and DACCON.

From: ANALOG DEVICES ADuC824: Errata Sheet (Rev 1.0 2000-12-01-)

What is the maximum clock frequency for the programmable PLL?

The programmable PLL can generate a clock frequency from 98kHz to 12MHz.

From: Analog Devices ADuC824 MicroConverter Quick Reference Guide

What is the conversion time for the DAC?

The DAC has a conversion time of 15 microseconds.

From: Analog Devices ADuC824 MicroConverter Quick Reference Guide

How often does the logger record temperature data?

The unit logs a precise temperature reading every 10 minutes.

From: Analog Devices ADuC824-Based Temperature Logger Technical Note

How much logged data can be stored?

The device stores the last 23 hours of temperature readings for upload to a PC.

From: Analog Devices ADuC824-Based Temperature Logger Technical Note