ANALOG DEVICES ADuC824: Errata Sheet (Rev 1.0 2000-12-01-)
The Analog Devices ADuC824 is a 16/24-bit ADC with an embedded Flash MCU. This errata sheet details specific issues found in all silicon branded as ADUC824BS, including known bugs and anomalies.
A critical issue identified involves indirect addressing modes where certain Special Function Registers (SFRs) cannot be read correctly using this method. The document provides a workaround involving the use of the accumulator register to bypass these restrictions for specific registers like ADCSTAT.
Analog Devices ADUC824 specifications
| Timeout Interval Range | 1/128 second to 255 hours |
|---|---|
| Supported MicroConverter Parts | ADuC814, ADuC816, ADuC824, ADuC831, ADuC832, ADuC834 |
| Clock Source | 32.768KHz watch crystal or r/c oscillator |
| Powerdown Capability | Remains active during powerdown |
Source: Analog Devices MicroConverter Time Interval Counter Application Note
All Analog Devices ADUC824 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
- Analog Devices ADuC824 MicroConverter Dual-Channel 16-/24-Bit ADCs with Embedded FLASH MCU Datasheet 68 p
- Analog Devices ADuC824 Smart Sensor Front-End Product Handbook 68 p
- Analog Devices ADuC824 Datasheet 68 p
- Analog Devices ADuC824 MicroConverter Dual-Channel 16-/24-Bit ADC with Embedded Flash MCU Handbook 68 p
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
How to use the product for one specific task, with worked examples.
Questions answered in these manuals
What is the revision status of this errata sheet?
This is Revision 1.0, dated December 2000, covering all silicon branded ADUC824BS.
From: ANALOG DEVICES ADuC824: Errata Sheet (Rev 1.0 2000-12-01-)
Which SFRs cannot be read using indirect addressing?
The following SFRs cannot be read using indirect addressing: ADCMODE, ADCOCON, ADCICON, SF, ICON, PSMCON, ADCSTAT, ADCOL/M/H, ADCIL/H, OFOL/M/H, OFIL/H, GNOL/M/H, GNIL/H, DACL/H, and DACCON.
From: ANALOG DEVICES ADuC824: Errata Sheet (Rev 1.0 2000-12-01-)
What is the maximum clock frequency for the programmable PLL?
The programmable PLL can generate a clock frequency from 98kHz to 12MHz.
From: Analog Devices ADuC824 MicroConverter Quick Reference Guide
What is the conversion time for the DAC?
The DAC has a conversion time of 15 microseconds.
From: Analog Devices ADuC824 MicroConverter Quick Reference Guide
How often does the logger record temperature data?
The unit logs a precise temperature reading every 10 minutes.
From: Analog Devices ADuC824-Based Temperature Logger Technical Note
How much logged data can be stored?
The device stores the last 23 hours of temperature readings for upload to a PC.
From: Analog Devices ADuC824-Based Temperature Logger Technical Note