Analog Devices MicroConverter Time Interval Counter Application Note

This document describes the working principle and configuration methods of the timer in the ADI MicroConverter® uC018 chip.


Analog Devices MicroConverter Time Interval Counter Application Note - cover page
Brand
Analog Devices
Category
microcontrollers
Document type
Application Note
Language
English
Pages
4
File format
PDF
File size
633 KB
Published
03 August, 2012
Updated
30 September, 2023
MD5 checksum
C42578C841DEAD8A3E3548065A1420EE

About this manual

This technical note explains the Time Interval Counter (TIC) feature found on specific Analog Devices MicroConverter parts. The TIC allows for counting longer intervals than standard timers, ranging from 1/128th of a second to 255 hours, and is clocked by an independent source to remain active during powerdown.

The document provides three specific application examples: waking the microcontroller from powerdown after a set interval, configuring the TIC to function as a real-time clock, and timing long intervals such as 96 hours. It includes C code examples for the ADuC832 to demonstrate these functions.

What's inside

  • Introduction
  • Time Interval Counter SFRs
  • Time Interval Counter Operation
  • Wake Up from Powerdown Example
  • Real Time Clock Example
  • Timing Long Intervals

Specifications

Timeout Interval Range1/128 second to 255 hours
Supported MicroConverter PartsADuC814, ADuC816, ADuC824, ADuC831, ADuC832, ADuC834
Clock Source32.768KHz watch crystal or r/c oscillator
Powerdown CapabilityRemains active during powerdown

Frequently asked questions

Can the Time Interval Counter wake the device from powerdown?

Yes, the TIC can remain active during powerdown and generate an interrupt to wake up the MicroConverter.

Which MicroConverter parts include the Time Interval Counter?

The TIC is present on the ADuC814, ADuC816, ADuC824, ADuC831, ADuC832, and ADuC834.