Analog Devices AD5750-1 Manuals

ManualLib has 4 documents for the Analog Devices AD5750-1: 4 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 4

Key facts

Model
AD5750-1
Industry
Industrial
Documents
4
Languages
EN
Last added
2012-08-03

Start here

DatasheetANALOG DEVICES AD5750/AD5750-1/AD5750-2 handbook

ANALOG DEVICES AD5750/AD5750-1/AD5750-2 handbook

Datasheet

AD5750/AD5750-1/AD5750-2 is an industrial current/voltage output driver with programmable ranges, which can be applied to process control, actuator control and PLC.

Read online

Analog Devices AD5750-1 specifications

Output current range4‑20 mA, 0‑20 mA, 0‑24 mA, ±20 mA, ±24 mA
Output voltage range0‑5 V, 0‑10 V, ±5 V, ±10 V (all with 20 % over‑range)
Supply voltage (AVDD/AVSS)±12 V to ±24 V (±10 %)
Resolution16 bit
Operating temperature range–40 °C to +105 °C

Source: Analog Devices AD5750/AD5750-1 DAC Datasheet

All Analog Devices AD5750-1 documents by type

Questions answered in these manuals

What output current ranges does the AD5750 support?

It supports 4‑20 mA, 0‑20 mA, 0‑24 mA, ±20 mA and ±24 mA output current ranges.

From: Analog Devices AD5750/AD5750-1 DAC Datasheet

What supply voltage range is required for the AD5750?

The device operates from ±12 V to ±24 V (±10 % tolerance) on the AVDD/AVSS pins.

From: Analog Devices AD5750/AD5750-1 DAC Datasheet

What current output ranges does the AD5750 support?

The AD5750 can output 4‑20 mA, 0‑20 mA, 0‑24 mA, +20 mA or +24 mA, selectable via software.

From: ANALOG DEVICES AD5750-1 English handbook

What supply voltage is required for the AD5750?

The device operates from a dual supply of +12 V to +24 V (±10 %) on AVop/AVss.

From: ANALOG DEVICES AD5750-1 English handbook

What serial interface does the AD5750 use?

The AD5750 uses a flexible serial digital interface that is SPI‑ and MICROWIRE‑compatible.

From: Analog Devices AD5750/AD5750-1 Industrial Current/Voltage Output Driver Datasheet

How does the device ensure a known state on power‑up?

It includes a power‑on reset function that sets the outputs to 0 V or tristate, and an asynchronous CLEAR pin can force zero‑scale output.

From: Analog Devices AD5750/AD5750-1 Industrial Current/Voltage Output Driver Datasheet