Key facts
- Brand
- Analog Devices
- Model
- AD596
- Industry
- Industrial
- Documents
- 2
- Languages
- EN
- Last added
- 2012-08-03
Start here

Analog Devices AD596/AD597 Thermocouple Amplifier Datasheet
The document details the specifications for the AD596 and AD597 thermocouple amplifiers, covering absolute maximum ratings, temperature measurement accuracy, and amplifier performance. It specifies operating parameters such as gain error, input offset voltage, and common-mode range for both Type J and Type K thermocouples.
Read onlineAnalog Devices AD596 specifications
| Operating Temperature Range | -55 to +125 °C |
|---|---|
| Nominal Transfer Function | 10 mV/°C |
| 3 dB Bandwidth | 15 kHz |
| Quiescent Current (AD596AH) | 160 µA |
| Usable Output Current | ±5 mA |
Source: Analog Devices AD596/AD597 Thermocouple Amplifier Datasheet
All Analog Devices AD596 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the accuracy of the temperature measurement?
The calibration error is ±4 °C over the specified temperature range.
From: Analog Devices AD596/AD597 Thermocouple Amplifier Datasheet
Is the alarm function available on all packages?
No, the alarm function is available only on the H package option.
From: Analog Devices AD596/AD597 Thermocouple Amplifier Datasheet
What supply voltage range can the AD596/AD597 operate from?
The devices can run from a single supply of 5 V to 36 V or from split supplies whose total does not exceed 36 V.
From: Analog Devices AD596/AD597 Thermocouple Conditioner Handbook
How can the alarm output be used?
The alarm output has a flexible format that can drive relays, LEDs, or TTL logic and can source or sink up to 20 mA.
From: Analog Devices AD596/AD597 Thermocouple Conditioner Handbook