Analog Devices AD596/AD597 Thermocouple Amplifier Datasheet

This document provides specifications and characteristics of AD596/AD597 Thermocouple Amplifiers. It is designed for Type J (AD596) and Type K (AD597) thermocouples and tested at +60°C and VS = 10 V. The document includes absolute maximum ratings, calibration error, gain error, closed loop gain, and other features.


Analog Devices AD596/AD597 Thermocouple Amplifier Datasheet - cover page
Brand
Analog Devices
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
8
File format
PDF
File size
773 KB
Published
03 August, 2012
Updated
28 September, 2023
Model
AD596
MD5 checksum
3E61816BA176BC96C306E4C20369C2A1

About this manual

The document details the specifications for the AD596 and AD597 thermocouple amplifiers, covering absolute maximum ratings, temperature measurement accuracy, and amplifier performance. It specifies operating parameters such as gain error, input offset voltage, and common-mode range for both Type J and Type K thermocouples.

What's inside

  • Absolute Maximum Ratings
  • Temperature Measurement
  • Amplifier Characteristics
  • Alarm Characteristics
  • Power Requirements
  • Output Voltage vs. Temperature
  • Temperature Proportional Output Mode
  • Connection Diagrams

Specifications

Operating Temperature Range-55 to +125 °C
Nominal Transfer Function10 mV/°C
3 dB Bandwidth15 kHz
Quiescent Current (AD596AH)160 µA
Usable Output Current±5 mA

Frequently asked questions

What is the accuracy of the temperature measurement?

The calibration error is ±4 °C over the specified temperature range.

Is the alarm function available on all packages?

No, the alarm function is available only on the H package option.

What is the ideal transfer function for the AD596?

The ideal transfer function is V OUT = 180.57 × (Vm – V a + (ambient in °C) × 53.21µV/°C + 235 µV).