Key facts
- Brand
- Analog Devices
- Model
- AD5934
- Industry
- Industrial
- Documents
- 3
- Languages
- EN
- Last added
- 2012-05-03
Start here

Analog Devices AD5934 Impedance Converter Datasheet
The AD5934 is a high‑precision 12‑bit impedance converter that combines an on‑board frequency generator with a 250 kSPS ADC. It offers programmable peak‑to‑peak excitation voltages, a 27‑bit frequency resolution, and a built‑in DSP for DFT processing, enabling accurate magnitude and phase measurements across a wide frequency range.
The device operates from 2.7 V to 5.5 V, supports an impedance range of 1 kΩ to 10 MΩ (with optional circuitry for 100 Ω‑1 kΩ), and provides up to 0.5 % total system accuracy. It is supplied in a 16‑lead SSOP package and includes detailed pin configurations, timing characteristics, and layout guidelines for optimal performance.
Analog Devices AD5934 specifications
| Impedance Range | 1 kΩ – 10 MΩ |
|---|---|
| Total System Accuracy | 0.5 % |
| Output Frequency Range | 1 Hz – 100 kHz |
| Output Frequency Resolution | <0.1 Hz |
| Supply Voltage | 2.7 V – 5.5 V |
| Power Consumption (Normal Mode) | 10 mA – 15 mA at 3.3 V |
| Signal‑to‑Noise Ratio | 60 dB |
| Total Harmonic Distortion | –52 dB |
| Operating Temperature Range | –40 °C to +125 °C |
| Package | 16‑Lead Shrink Small Outline Package (SSOP) |
All Analog Devices AD5934 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What supply voltage range does the AD5934 require?
The AD5934 operates from 2.7 V to 5.5 V.
What impedance range can the AD5934 measure?
It can measure impedances from 1 kΩ up to 10 MΩ, with optional circuitry for 100 Ω to 1 kΩ.
What is the impedance measurement range of the AD5934?
The device can measure impedances from 0.001 Ω up to 10 MΩ.
What supply voltage range does the AD5934 support?
It operates from 2.7 V to 5.5 V.
What supply voltage range does the AD5934 support?
The AD5934 operates from 2.7 V to 5.5 V supply voltage.
What is the total system accuracy of the AD5934?
The device provides a total system accuracy of 0.5 %.