Key facts
- Brand
- Agilent
- Model
- 6850 Series II
- Documents
- 4
- Languages
- EN
- Last added
- 2012-07-04
Start here

Agilent Technologies 6850 Series II GC User Information
The document serves as a comprehensive user guide for the Agilent 6850 Series II Gas Chromatograph (GC). It covers essential topics including important safety warnings regarding high voltages, hot parts, and hydrogen gas usage. The manual details the instrument's display and keypad features, method loading capabilities, and run control functions.
Read onlineAgilent 6850 Series II specifications
| Width (Standard) | 283 mm |
|---|---|
| Column Oven Dimensions | 202 x 200 x 105 mm (HWD) |
| Column Basket Diameter | 130 mm |
| Temperature Setpoint Resolution | 1°C |
| Maximum Run Time | 999.99 min |
| TCD Minimum Detectable | <400 pg propane/mL helium carrier |
| Micro-ECD MDL | <0.008 pg/s lindane |
Source: Agilent 6850 Series II Network GC System Specifications
All Agilent 6850 Series II documents by type
Mounting, wiring and first power-up. Read it before the hardware goes in.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the ambient operating temperature range?
The ambient operating temperature ranges from 15 °C to 35 °C.
From: Agilent 6850 Series II Network GC System Specifications
Is the system ready for automatic liquid sampling?
Yes, it is ALS-ready with a built-in controller for the G2880 autosampler or Agilent 7683/7693 autoinjector.
From: Agilent 6850 Series II Network GC System Specifications
Which Agilent models are compatible with this upgrade kit?
These kits can only be installed on 6850 Series II GCs (serial number 43-10413001 or later).
From: Agilent 6850 Series II Fast Oven Upgrade Kit Installation Guide
Which Agilent GC serial numbers are compatible with this upgrade kit?
These kits can only be installed on 6850 Series II GCs that have a serial number of 43-10413001 or later.
From: Agilent 6850 Series II Fast Oven Upgrade Kit Installation Guide
What safety precautions are needed when working with hydrogen gas?
Leak test all connections, lines, and valves before operating the instrument. Always turn off the hydrogen supply at its source before working on the instrument.
From: Agilent Technologies 6850 Series II GC User Information
What are the restrictions for owners of a General License pECD?
Owners may not open the pECD cell, shall not modify the cell in any manner, and shall not use any solvent to internally clean the cell.
From: Agilent Technologies 6850 Series II GC User Information