Datasheet 2

Key facts

Brand
Philips
Model
BUK208-50Y
Industry
Industrial
Documents
2
Languages
EN
Last added
2012-07-06

Start here

PHILIPS BUK208-50Y; BUK213-50Y handbook(1)

PHILIPS BUK208-50Y; BUK213-50Y handbook(1)

Datasheet 16 pages · 90 KB · EN

The document describes the BUK212-50Y and BUK217-50Y, which are monolithic temperature and overload protected single high-side power switches based on TOPFET Trench technology. These devices are available in SOT263B-01 or SOT426 (D 2-PAK) packages.

Read online

Philips BUK208-50Y specifications

Battery-ground operating voltage (Min)5.5 V
Load current (Max)44 A
Self-limiting load current (Min)47 A
Battery-ground supply voltage (Max)50 V
Total power dissipation (Tmb≤25°C) (Max)115 W
Storage temperature range-55 to +175 °C

Source: PHILIPS BUK208-50Y; BUK213-50Y handbook(1)

All Philips BUK208-50Y documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the nominal load current for ISO?

The nominal load current (ISO) ranges from 25 A to a maximum of 44 A.

From: PHILIPS BUK208-50Y; BUK213-50Y handbook(1)

Does this device have overtemperature protection?

Yes, the device includes overtemperature protection with a threshold junction temperature of 150°C to 190°C.

From: PHILIPS BUK208-50Y; BUK213-50Y handbook(1)

What are the available packages for these switches?

The BUK212-50Y is available in SOT263B-01, and the BUK217-50Y is available in SOT426 (D2-PAK).

From: PHILIPS BUK208-50Y; BUK213-50Y handbook

What types of loads are these switches designed for?

They are intended for 12 V and 24 V grounded loads, including inductive loads.

From: PHILIPS BUK208-50Y; BUK213-50Y handbook