Agilent C-18 Manuals

ManualLib has 5 documents for the Agilent C-18: 4 application notes. Every file can be read online or downloaded as a PDF for free.

Application Note 4

Key facts

Brand
Agilent
Model
C-18
Industry
Electronics
Documents
5
Languages
EN
Last added
2012-07-04

Start here

Agilent Eclipse XDB Cartridge Columns Data Sheet

Agilent Eclipse XDB Cartridge Columns Data Sheet

Datasheet 2 pages · 45 KB · EN

This document provides a data sheet for Agilent Eclipse XDB-C8 and -C18 microparticulate packings. These columns utilize eXtra-Dense Bonding (XDB) technology on ultra-pure silica supports to protect against dissolution at intermediate pH levels, making them suitable for separating acidic, basic, and highly polar compounds via reversed-phase liquid chromatography.

Read online

Agilent C-18 specifications

pH Range2-9 (best 3-8)
Silica Support Surface Area180 m²/g
Controlled Pore Size80A
Maximum Column Temperature<40 °C

Source: Agilent Eclipse XDB Cartridge Columns Data Sheet

All Agilent C-18 documents by type

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What are the recommended wash volumes for different column lengths?

Typical wash volumes are 12.5 mL for a 75 mm length, 25 mL for a 150 mm length, and 41 mL for a 250-mm length.

From: Agilent Eclipse XDB Cartridge Columns Data Sheet

What solvent is used to ship ZORBAX and Eclipse columns?

The shipping solvent is water/acetonitrile or water/methanol.

From: Agilent Eclipse XDB Cartridge Columns Data Sheet

What is the range of concentrations tested for linearity?

The study covers a wide range of approximately 150 ng to 5,000 ng.

From: Agilent Detector linearity testing for Aripiprazole quality control with the Agilent 1120 Compact LC ZORBAX C-18 columns Application Note

What is the relative standard deviation (RSD) for retention times?

The RSD for retention times was less than 0.07% for all six linearity levels.

From: Agilent Detector linearity testing for Aripiprazole quality control with the Agilent 1120 Compact LC ZORBAX C-18 columns Application Note

What is the total run time for the analysis including equilibration?

The total run time, which includes re-equilibration, can be limited to 14 minutes.

From: Agilent In-process control for Aripiprazole manufacturing with the Agilent 1120 Compact LC ZORBAX C-18 columns Application Note

What wavelength was used for the variable wavelength detector?

The VWD was set to detect at a wavelength of 254 nm.

From: Agilent In-process control for Aripiprazole manufacturing with the Agilent 1120 Compact LC ZORBAX C-18 columns Application Note