Datasheet

MOC301XM, MOC302XM are 6-Pin DIP random-phase optoisolators triac driver outputs (250/400 volt peak). They feature excellent IFT stability, high isolation voltage, UL recognition, and VDE recognition. They are suitable for industrial controls, solenoid/valve controls, traffic lights, static AC power switches, vending machines, incandescent lamp dimmers, solid state relays, motor control, and lamp ballasts.

Read online

Fairchild MOC3020M specifications

Isolation Surge Voltage (VISO)7500 Vac(pk)
Peak Blocking Voltage250 V (MOC301X) / 400 V (MOC302X)
Continuous Forward Current (IF)60 mA
Reverse Voltage (VR)3 V
Total Device Power Dissipation (PD)330 mW @ 25 °C
Storage Temperature Range-40 °C to +150 °C
Operating Temperature Range-40 °C to +85 °C

Source: Fairchild MOC3010M/MOC3011M/MOC3012M/MOC3020M/MOC3021M/MOC3022M/MOC3023M Datasheet

All Fairchild MOC3020M documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the maximum isolation voltage for the MOC3010M series?

The isolation surge voltage rating is 7500 Vac(pk).

From: Fairchild MOC3010M/MOC3011M/MOC3012M/MOC3020M/MOC3021M/MOC3022M/MOC3023M Datasheet

What are the peak blocking voltages for the MOC3010M and MOC3020M devices?

MOC3010M devices have a 250 V peak blocking voltage, while MOC3020M devices have a 400 V peak blocking voltage.