Analog Devices AD584 Pin Programmable Precision Voltage Reference Datasheet
The AD584 is an 8-terminal precision voltage reference that allows for pin programmable selection of four popular output voltages: 10.000 V, 7.500 V, 5.000 V, and 2.500 V. It utilizes laser wafer trimming to ensure high accuracy without requiring external components. The device features a unique strobe terminal that permits the supply to be switched on or off with low power.
Read onlineAnalog Devices AD584 specifications
| Output Voltages | 10.000 V, 7.500 V, 5.000 V, and 2.500 V |
|---|---|
| Temperature Coefficient (AD584K) | 15 ppm/°C maximum |
| Quiescent Current | 1.0 mA maximum |
| Output Current Capability | 10 mA |
| Operating Temperature Range (AD584J/K) | 0°C to +70°C |
| Operating Temperature Range (AD584S/T) | -55°C to +125°C |
Source: Analog Devices AD584 Pin Programmable Precision Voltage Reference Datasheet
All Analog Devices AD584 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What output voltages can be selected on the AD584?
The device offers pin programmable selection of 10.000 V, 7.500 V, 5.000 V, and 2.500 V.
From: Analog Devices AD584 Pin Programmable Precision Voltage Reference Datasheet
Does the AD584 require external components?
No, it is designed to operate without external components.
From: Analog Devices AD584 Pin Programmable Precision Voltage Reference Datasheet
What output voltages does the AD584 provide?
It offers four programmable output voltages: 10.000 V, 7.500 V, 5.000 V, and 2.500 V.
From: Analog Devices AD584 Precision Voltage Reference Datasheet
What is the quiescent current of the AD584?
Typical quiescent current is 0.75 mA, with a maximum of 1.0 mA.
From: Analog Devices AD584 Precision Voltage Reference Datasheet
What are the four programmable output voltages of the AD584?
The AD584 can be programmed to output 10.000 V, 7.500 V, 5.000 V, or 2.500 V.
From: Analog Devices AD584 Precision Voltage Reference Datasheet
How does the strobe terminal turn the AD584 output off?
Pulling the strobe pin low to less than 200 mV disables the output, reducing the device’s current drain to about 100 µA.
From: Analog Devices AD584 Precision Voltage Reference Datasheet