STMicroelectronics STC3100 Manuals

ManualLib has 2 documents for the STMicroelectronics STC3100: 2 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 2

Key facts

Model
STC3100
Industry
Industrial
Documents
2
Languages
EN
Last added
2012-08-10

Start here

STMicroelectronics STC3100 Battery Monitor IC Datasheet

STMicroelectronics STC3100 Battery Monitor IC Datasheet

Datasheet 21 pages · 279 KB · EN

The STC3100 is a battery monitor IC designed for single-cell Li-ion batteries. It includes hardware functions to implement a gas gauge for battery charge monitoring based on a programmable 12- to 14-bit A/D converter. The device monitors critical parameters such as voltage, temperature, and current.

Read online

STMicroelectronics STC3100 specifications

Operating temperature-40 to 85 °C
A/D converter resolution12 or 14 bits
Input voltage range+/- 80 mV
Time base frequency32768 Hz
RAM size32 bytes
Device ID8-byte unique
Maximum current2.5 A
Maximum capacity+/- 7000 mAh
Current resolution0.2 mAh

Source: STMicroelectronics STC3100 Battery Monitor IC Datasheet

All STMicroelectronics STC3100 documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Application Note 1

How to use the product for one specific task, with worked examples.

Questions answered in these manuals

How is the STC3100 programmed?

The device is programmable through the I2C interface.

From: STMicroelectronics STC3100 Battery Monitor IC Datasheet

What is the operating current consumption?

The average operating current consumption is 100 uA over 4 seconds.

From: STMicroelectronics STC3100 Battery Monitor IC Datasheet

What is the function of the Reg resistor in the STC3100 circuit?

The Reg resistor is used to sense the current flowing into or from the battery, and its value must be selected so the voltage drop does not exceed +/-80 mV.

From: AN3064 Using the STC3100 Battery Monitor for Gas Gauge Applications

How does the STC3100 handle timebase accuracy?

The device can operate from an internal oscillator or use an external RTC signal. An external square wave signal provides higher accuracy than the internal oscillator.

From: AN3064 Using the STC3100 Battery Monitor for Gas Gauge Applications