Philips 277V Manuals

ManualLib has 3 documents for the Philips 277V (Other Electronics): 1 other, 1 datasheet, 1 installation guide. Every file can be read online or downloaded as a PDF for free.

Other 1Datasheet 1Installation Guide 1

Key facts

Brand
Philips
Model
277V
Documents
3
Languages
EN
Last added
2023-10-16

Start here

Philips Surge Protection Device 277V Design-in Guide

Philips Surge Protection Device 277V Design-in Guide

Other 14 pages · 2 MB · EN

This document serves as a design-in guide for the Philips Surge Protection Device 277V (SPD), intended for integration into Class I and Class II outdoor luminaires. It explains how the device protects lighting installations from damaging voltage spikes, including those caused by lightning strikes, by limiting differential and common mode surge voltages.

Read online

Philips 277V specifications

Protection Level (Differential Mode)1.6 kV between L and N
Protection Level (Common Mode)2.5 kV
Nominal Currentup to 5kA
Single Strike Capability5 to 10kA
Wire Cross Section0.5 - 4 mm2
Mounting Screw TypeM8
Product Length89 mm
Product Width41 mm
Product Height38 mm

Source: Philips Surge Protection Device 277V Design-in Guide

All Philips 277V documents by type

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Installation Guide 1

Mounting, wiring and first power-up. Read it before the hardware goes in.

Questions answered in these manuals

What type of surge protection device is the Philips 277V?

It is a Type 3 product characterized by a combination of voltage waves (1.2/50 μs) and current waves (8/20 μs).

From: Philips Surge Protection Device 277V Design-in Guide

Can the device be used with different lamp types?

Yes, it can be used in combination with electronic drivers and different lamp types such as LEDs, HID, and fluorescent lamps.

From: Philips Surge Protection Device 277V Design-in Guide

What type of MOSFET is the BLF277?

It is a Silicon N-channel enhancement mode vertical D-MOS transistor.

From: Philips BLF277 VHF Power MOS Transistor Data Sheet

What are the typical operating conditions for Class-B operation?

The device operates at 175 MHz with a supply voltage of 50 V and a drain current of 0.1 A.

From: Philips BLF277 VHF Power MOS Transistor Data Sheet

Who should install the Powercore Downlight?

The fixture must be installed by a qualified electrician.

From: PHILIPS 100 120 220-240 277 VAC Installation Guide

Do I need to turn off power before installing?

Yes, ensure the main power supply is off before any installation or wiring.

From: PHILIPS 100 120 220-240 277 VAC Installation Guide