Key facts

Model
REF03
Industry
Industrial
Documents
3
Languages
EN
Last added
2012-08-03

Start here

DatasheetANALOG DEVICES REF01/REF02/REF03 handbook

ANALOG DEVICES REF01/REF02/REF03 handbook

Datasheet

The document describes the features and characteristics of the precision voltage references REF01/REF02/REF03, including high output accuracy, adjustable output, excellent temperature stability, low noise, high supply voltage range, low supply current, and high load-driving capability. They are suitable for precision data systems, high-resolution converters, industrial process control systems, precision instruments, and military and aerospace applications.

Read online

Analog Devices REF03 specifications

Output Voltage Tolerance±0.2 % to ±0.6 %
Temperature Coefficient50 ppm/°C
Line Regulation50 ppm/V
Supply Current (quiescent)14 mA max

Source: Analog Devices REF-03 Voltage Reference Datasheet

All Analog Devices REF03 documents by type

Datasheet 3

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the maximum supply current of the REF-03?

The device draws up to 14 mA of supply current.

From: Analog Devices REF-03 Voltage Reference Datasheet

What is the temperature coefficient of the REF-03 output voltage?

The output voltage temperature coefficient is 50 ppm/°C.

From: Analog Devices REF-03 Voltage Reference Datasheet

What is the typical output voltage of the REFO3?

The REFO3 provides a stable 2.5 V output.

From: ANALOG DEVICES REF03 handbook

What input voltage range does the REFO3 support?

It operates from 4.5 V up to 33 V.