Key facts

Model
REF02
Industry
Industrial
Documents
5
Languages
EN
Last added
2012-08-03

Start here

DatasheetANALOG DEVICES AN-18 Thermometer Applications of the REF-02 handbook

Analog Devices REF02 specifications

Output Voltage5 V ±0.3 %
Temperature Coefficient1.96 mV/°C
Output Voltage Noise15 µV p‑p (0.1 Hz‑10 Hz)
Low Supply Current1.4 mA max
Input Voltage Range7 V to 40 V
Maximum Load Current10 mA

Source: Analog Devices REF02 Precision Voltage Reference/Temperature Transducer Datasheet

All Analog Devices REF02 documents by type

Questions answered in these manuals

What is the output voltage of the REF02?

The REF02 provides a 5 V output with a tolerance of ±0.3 %.

From: Analog Devices REF02 Precision Voltage Reference/Temperature Transducer Datasheet

What is the temperature coefficient of the REF02?

The temperature coefficient is 1.96 mV per degree Celsius.

From: Analog Devices REF02 Precision Voltage Reference/Temperature Transducer Datasheet

What is the typical output voltage of the REFO2?

The REFO2 provides a typical output voltage of 5.000 V.

From: ANALOG DEVICES REF02 handbook (1)

What is the temperature stability of the REFO2?

The device achieves an excellent temperature stability of 8.5 ppm/°C max.

From: ANALOG DEVICES REF02 handbook (1)

How much supply current does the REF02 draw?

The REF02 draws up to 1.4 mA of supply current.

From: Analog Devices REF02 Precision Voltage Reference Datasheet

What input voltage range does the REF02 support?

The device operates from 7 V to 40 V input voltage.

From: Analog Devices REF02 Precision Voltage Reference Datasheet