Analog Devices ADR1581 Manuals

ManualLib has 2 documents for the Analog Devices ADR1581: 2 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 2

Key facts

Model
ADR1581
Industry
Industrial
Documents
2
Languages
EN
Last added
2012-08-03

Start here

ANALOG DEVICES ADR1581: 1.25 V Micropower Precision Shunt Voltage Reference Data Sheet (Rev 0 2007-05-01-) handbook

ANALOG DEVICES ADR1581: 1.25 V Micropower Precision Shunt Voltage Reference Data Sheet (Rev 0 2007-05-01-) handbook

Datasheet 12 pages · 897 KB · EN

The ADR1581 is a micropower, precision shunt voltage reference available in the SOT-23 package. It provides a stable 1.250 V output with an initial accuracy of ±0.12% maximum and a temperature drift of ±50 ppm/°C maximum over the industrial temperature range of −40°C to +85°C.

The device is designed for applications requiring low noise, low output impedance, and wide operating current ranges. It is suitable for use in portable battery-powered equipment, cellular phones, notebook computers, PDAs, GPSs, DMMs, computer workstations, industrial transmitters, PCMCIA cards, and automotive systems.

Read online

Analog Devices ADR1581 specifications

Initial Accuracy±0.12% maximum
Temperature Drift±50 ppm/°C maximum
Output Impedance0.5 Ω maximum
Operating Temperature Range-40°C to +85°C

Source: ANALOG DEVICES ADR1581: 1.25 V Micropower Precision Shunt Voltage Reference Data Sheet (Rev 0 2007-05-01-) handbook

All Analog Devices ADR1581 documents by type

Questions answered in these manuals

What is the output voltage of the ADR1581?

The ADR1581 provides an accurate 1.250 V output.

From: ANALOG DEVICES ADR1581: 1.25 V Micropower Precision Shunt Voltage Reference Data Sheet (Rev 0 2007-05-01-) handbook

What is the operating current range for the device?

The input currents must be between 60 μA and 10 mA.

From: ANALOG DEVICES ADR1581: 1.25 V Micropower Precision Shunt Voltage Reference Data Sheet (Rev 0 2007-05-01-) handbook

What is the operating temperature range of the ADR1581?

The device is specified to operate from –40 °C to +85 °C, with an absolute maximum range of –55 °C to +125 °C.