Analog Devices ADR1500 Manuals

ManualLib has 2 documents for the Analog Devices ADR1500: 2 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 2

Key facts

Model
ADR1500
Industry
Industrial
Documents
2
Languages
EN
Last added
2012-08-03

Start here

DatasheetANALOG DEVICES ADR1500: 1.2875 V Micropower Shunt Voltage Reference Data Sheet (Rev 0 2006-01-01-)

Analog Devices ADR1500 specifications

Typical Output Voltage1.2875 V
Reverse Voltage Temperature Drift220 ppm/°C (max)
Minimum Operating Current50 pA
Output Noise (10 Hz‑10 kHz)20 µV rms
Turn‑On Settling Time (to 0.1 %)5 µs
Output Voltage Hysteresis80 pV
Specified Temperature Range–40 °C to +85 °C
Operating Temperature Range–55 °C to +125 °C
Maximum Reverse Current (damage limit)25 mA

Source: Analog Devices ADR1500 Voltage Reference Datasheet

All Analog Devices ADR1500 documents by type

Questions answered in these manuals

What is the typical output voltage of the ADR1500?

The ADR1500 provides a typical output voltage of 1.2875 V.

From: Analog Devices ADR1500 Voltage Reference Datasheet

What temperature range can the ADR1500 operate in?

The specified temperature range is –40 °C to +85 °C, and the device can operate from –55 °C to +125 °C.

From: Analog Devices ADR1500 Voltage Reference Datasheet