ANALOG DEVICES ADR121/ADR125/ADR127: Precision Micropower LD0 Voltage References in TSOT Data Sheet

ANALOG DEVICES ADR121/ADR125/ADR127: Precision Micropower LD0 Voltage References in TSOT Data Sheet

Datasheet 20 pages · 598 KB · EN

The document describes a family of micropower, high-precision, series mode band gap references (ADR121/ADR125/ADR127) available in a tiny TSOT package. These devices feature patented temperature-drift curvature correction to minimize output voltage nonlinearity and offer low dropout performance suitable for battery-powered applications.

Read online

Analog Devices ADR127 specifications

Maximum Temperature Coefficient25 ppm/°C (A Grade)
Low Dropout Voltage (ADR121/ADR125)300 mV
High Output Current+5 mA / −2 mA
Typical Operating Current85 μA
Operating Temperature Range−40°C to +125°C

Source: ANALOG DEVICES ADR121/ADR125/ADR127: Precision Micropower LD0 Voltage References in TSOT Data Sheet

All Analog Devices ADR127 documents by type

Questions answered in these manuals

What is the dropout voltage for ADR127?

The dropout voltage for ADR127 requires 1.45 V above the nominal output voltage.

From: ANALOG DEVICES ADR121/ADR125/ADR127: Precision Micropower LD0 Voltage References in TSOT Data Sheet

What is the quiescent current at VIN = 18 V?

The typical quiescent current is 125 μA when the input voltage is 18 V.

From: ANALOG DEVICES ADR121/ADR125/ADR127: Precision Micropower LD0 Voltage References in TSOT Data Sheet

What is the typical output voltage of the ADR127?

The ADR127 provides a typical output voltage of 1.25 V (A‑grade).

From: Analog Devices ADR127 LDO Voltage Reference Datasheet

What dropout voltage does the ADR127 require?

The device needs a dropout of about 1.45 V above the nominal output when no load is present.

From: Analog Devices ADR127 LDO Voltage Reference Datasheet