Key facts
- Brand
- Analog Devices
- Model
- ADR130
- Industry
- Industrial
- Documents
- 2
- Languages
- EN
- Last added
- 2012-08-03
Start here

Analog Devices ADR130 Precision Voltage Reference Datasheet
The ADR130 is described as the industry's first family of tiny, micropower, low voltage, high precision voltage references. It features an initial accuracy of up to ±0.70% (A grade) or ±0.35% (B grade) and operates with a typical quiescent current of 80 µA.
Read onlineAnalog Devices ADR130 specifications
| Initial Accuracy (A Grade) | +0.70% maximum |
|---|---|
| Initial Accuracy (B Grade) | +0.35% maximum |
| Temperature Coefficient (A Grade) | 50 ppm/°C |
| Temperature Coefficient (B Grade) | 25 ppm/°C |
| Operating Current | 80 µA typical |
| Input Voltage Range | 2.0 V to 18 V |
| Operating Temperature Range | -40°C to +125°C |
Source: Analog Devices ADR130 Precision Voltage Reference Datasheet
All Analog Devices ADR130 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the typical operating current of the ADR130?
The device features a low operating current of 80 µA typical.
From: Analog Devices ADR130 Precision Voltage Reference Datasheet
What is the input voltage range for the ADR130?
The device accepts an input voltage ranging from 2.0 V to 18 V.
From: Analog Devices ADR130 Precision Voltage Reference Datasheet
What is the typical output voltage of the ADR130?
The ADR130 provides a typical output of 0.5 V for the A‑grade version and 1.0 V for the B‑grade version.
What is the quiescent current of the ADR130?
The device draws about 80 µA of quiescent current under no‑load conditions.