Agilent ZORBAX SB-C18 Rapid-Resolution Column Application Note

This article describes the use of short column lengths for high performance liquid chromatography (HPLC) and discusses some of the advantages of this method. Short column lengths can reduce analysis times, increase peak heights, and allow for some tolerable loss in resolution. This method is particularly well suited for high-throughput analysis and can reduce solvent consumption and enhance sensitivity for mass-limited samples.


Agilent ZORBAX SB-C18 Rapid-Resolution Column Application Note - cover page
Brand
Agilent
Category
Other
Document type
Product Leaflet
Language
English
Pages
2
File format
PDF
File size
410 KB
Published
03 July, 2012
Updated
30 September, 2023
MD5 checksum
BE99ED9F36F6421229C1BE6B81437CEF

About this manual

This document discusses the application of low-volume columns in High-Performance Liquid Chromatography (HPLC). It explains that shortening column length reduces analysis time and solvent consumption without altering selectivity or retention factors, provided extra-column effects are minimized. The text highlights that this approach is particularly valuable for high-speed analyses and LC/MS applications involving mass-limited samples.

The document presents experimental data analyzing analgesics using a series of Agilent ZORBAX SB-C18 Rapid-Resolution columns with varying lengths (150 mm down to 15 mm). Results indicate that switching from a 150-mm to a 15-mm column reduces analysis time and solvent use ten-fold, with a tolerable loss of resolution.

What's inside

  • Application
  • Highlights
  • Conditions
  • Resolution Equation
  • Column Length Effects

Specifications

Column Lengths Tested150 mm, 75 mm, 50 mm, 30 mm, and 15 mm
Particle Size3.5 ym
Column Dimensions4.6 x 150 mm
Mobile PhaseACN : H2O, 1% formic acid (32:68); pH 2.3
Flow Rate1.0 mL / min
Temperature30°C
Injection Volume5 pL

Frequently asked questions

What are the benefits of using low-volume columns?

Low-volume columns are valuable for high-speed analyses, decreasing solvent consumption, and enhancing sensitivity for mass-limited samples commonly used for LC/MS applications.

How much does analysis time reduce when switching to a shorter column?

Switching from a 150-mm to a 15-mm column reduces analysis time and solvent use ten-fold.

Does shortening column length alter selectivity or retention factors?

No, shortening column length does not alter k' or selectivity (a) obtained when using the longer-column method.

Download PDF (410 KB)