Agilent ZORBAX SB-C18 RRHT Threaded Column Datasheet

The Agilent ZORBAX SB-C18 RRHT Threaded Column is designed for high-pressure operation (up to 600 bar) and is packed with a high-performance microparticulate C18 packing for high-speed reversed phase HPLC. The StableBond packing is made by chemically bonding a sterically-protected C18 stationary phase to a specially prepared, high purity ZORBAX porous silica microsphere. The special ZORBAX silica support is designed to reduce or eliminate strong adsorption of basic compounds. The densely covered, sterically protected, diisobutyl n-octadecylsilane stationary phase is chemically stable and gives longer column life. As a result, ZORBAX SB-C18 is a stable, reversed-phase packing that can be used for basic, neutral, or acidic samples. It is particularly well suited for use with aggressive mobile phases (for example, pH <2, high ionic strength, ion-pair additives, etc.) since the steric protection of the bonded phase resists degradation caused by such mobile phases. This material has also been shown to be stable when operated at temperatures up to 90 °C. These characteristics are particularly important for use in methods that need long-term stability and reproducibility. ZORBAX SB-C18 is especially suited in applications that use high-sensitivity detectors that require low backgrounds (for example, mass spectrometers). The uniform, spherical, ZORBAX SB-C18 particles have a controlled pore size of 80Å.


Agilent ZORBAX SB-C18 RRHT Threaded Column Datasheet - cover page
Brand
Agilent
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
2
File format
PDF
File size
77 KB
Published
04 July, 2012
Updated
29 September, 2023
MD5 checksum
69589420FC711390C4DB4F2BEDEC964A

About this manual

The Agilent ZORBAX SB-C18 RRHT threaded columns are specially designed for higher pressure operation (up to 600 bar) and are packed with a high performance microparticulate C18 packing for high-speed reversed phase HPLC. The StableBond packing is made by chemically bonding a sterically-protected C18 stationary phase to a specially prepared, high purity ZORBAX porous silica microsphere.

What's inside

  • General Description
  • Operating Conditions
  • Column Characteristics
  • Safety Considerations
  • Operational Guidelines
  • Mobile Phase Selection
  • Applications
  • Column Care
  • Storage Recommendations
  • Agilent Ordering Information

Specifications

Maximum operating pressure600 bar (9000 psi)
Maximum operating temperature90 °C
Particle size1.8 um
Pore size80A
Compatible pH rangepH 0.8 to 8.0

Frequently asked questions

What is the maximum operating pressure for these columns?

The maximum operating pressure is 600 bar (9000 psi).

What is the recommended storage solvent for long term storage?

Long term storage should be in a pure organic solvent, preferably an aprotic liquid such as 100% acetonitrile.

Can these columns be used with basic samples?

Yes, ZORBAX SB-C18 is especially suited for basic, neutral, or acidic samples.