Agilent 971-FP Manuals

ManualLib has 6 documents for the Agilent 971-FP: 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Brand
Agilent
Model
971-FP
Industry
Industrial
Documents
6
Languages
EN
Last added
2012-07-05

Start here

Agilent 971-FP Flash Purification System IntelliFlash Guide Me Scale-Up Feature Guide

Agilent 971-FP Flash Purification System IntelliFlash Guide Me Scale-Up Feature Guide

User Manual 4 pages · 235 KB · EN

The document describes the 'Scale Up' feature within the IntelliFlash software for the Agilent 971-FP Flash Purification System. This feature allows users to transfer method details between Agilent SuperFlash columns of different sizes while maintaining compound purity and yield, without requiring manual calculations of column dimensions or flow rates.

The guide details the mathematical principles behind the scaling process, specifically the equations used to calculate flow rate for the same linear velocity and gradient duration for different column lengths. It provides instructions on how to use the software interface to select historical runs or specify parameters to automatically generate new run conditions for scaled-up separations.

Read online

Agilent 971-FP specifications

Column LengthLongest column in the SuperFlash column product range
Media Type35 µm silica
Flow Rate40 mL/min
Purification Range1.6 g to 16 g
Aspect Ratio16.2:1

Source: Agilent 971-FP Flash Purification System Technical Overview

All Agilent 971-FP documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Application Note 1

How to use the product for one specific task, with worked examples.

Service Manual 1

Disassembly, diagnostics and part numbers, for repair.

Questions answered in these manuals

How does dual detection prevent sample loss?

It allows the isolation of non-UV active compounds that would otherwise remain undetected by a UV detector alone.

From: Varian 971-FP Flash Chromatography Detection Method Application Note

What instruments are used in this demonstration?

A Varian 385-LC ELS detector coupled with a Varian 971-FP flash instrument.

From: Varian 971-FP Flash Chromatography Detection Method Application Note

Can the SF25-160 g Si 35 column be run at 40 mL/min?

Yes, it can be run at 40 mL/min without exceeding the maximum operating pressure of the Agilent 971-FP instrument.

From: Agilent 971-FP Flash Purification System Technical Overview

What is the purification range for the SF25-160 g Si 35 column?

It is designed for the purification of between 1.6 g and 16 g of a complex mix.

From: Agilent 971-FP Flash Purification System Technical Overview

Does the software require manual calculation of column dimensions for scale-up?

No, the software automatically supplies the necessary calculations for flow rate and duration.

From: Agilent 971-FP Flash Purification System IntelliFlash Guide Me Scale-Up Feature Guide

What parameters are critical for successful purification scale-up?

The flow rate used to run the column and the number of column volumes needed for the gradient.

From: Agilent 971-FP Flash Purification System IntelliFlash Guide Me Scale-Up Feature Guide