Agilent 971-FP Flash Purification System Technical Overview

The document describes the features and characteristics of the Agilent 971-FP Flash Purification System and its application in discovery applications. The system allows purification of complex samples by running the longest Agilent SuperFlash column at a flow rate of 40 mL/min without exceeding the maximum operating pressure. Agilent offers a complete flash purification solution including the 971-FP instrument, IntelliFlash software, and SuperFlash columns for drug discovery applications. These applications typically require purification of milligram to several gram quantities of a synthetic compound from a synthesis mix. To achieve high efficiency for related compounds, smaller particle media and longer column lengths are used. The SuperFlash SF25-160 g Si 35 column is a normal phase column packed with high efficiency 35 µm silica. It has an aspect ratio of 16.2:1 and is designed for purifying complex mixes in the range of 1.6 g to 16 g. Investigations of the operating pressure of this column determined the maximum pressure reached during purification using the IntelliFlash software at the default flow rate for this column id and a gradient from 0 to 100% ethyl acetate.


Agilent 971-FP Flash Purification System Technical Overview - cover page
Brand
Agilent
Category
Other
Document type
Product Leaflet
Language
English
Pages
2
File format
PDF
File size
34 KB
Published
05 July, 2012
Updated
28 September, 2023
Model
971-FP
MD5 checksum
0816E04384F69AA8A5DEC12735C8923D

About this manual

This document provides a technical overview of the Agilent 971-FP Flash Purification System, specifically addressing the capability of the longest SuperFlash column (SF25-160 g Si 35) for drug discovery applications. It details how the system can purify complex samples ranging from 1.6 g to 16 g using high-efficiency 35 µm silica media.

What's inside

  • Purification for discovery applications
  • SuperFlash column specifications
  • Operating pressure investigations
  • IntelliFlash software
  • Gradient composition data
  • Maximum operating pressure limits

Specifications

Column LengthLongest column in the SuperFlash column product range
Media Type35 µm silica
Flow Rate40 mL/min
Purification Range1.6 g to 16 g
Aspect Ratio16.2:1

Frequently asked questions

Can the SF25-160 g Si 35 column be run at 40 mL/min?

Yes, it can be run at 40 mL/min without exceeding the maximum operating pressure of the Agilent 971-FP instrument.

What is the purification range for the SF25-160 g Si 35 column?

It is designed for the purification of between 1.6 g and 16 g of a complex mix.