Key facts
- Brand
- Agilent
- Model
- 225-MS
- Industry
- Industrial
- Documents
- 6
- Languages
- EN
- Last added
- 2012-07-04
Start here

Agilent Technologies 210-MS 220-MS 225-MS GC/MS Ion Trap Mass Spectrometer MS Workstation Version 6 Software Operation Manual
This document is the User's Guide and Reference Manual for the MS Workstation Version 6 software. It covers system configuration, instrument control, method creation and editing, data acquisition, calibration procedures, and report generation.
The manual details operations for controlling various mass spectrometers (210-MS, 220-MS, 225-MS) and gas chromatographs (431-GC, 450-GC). It includes instructions on using the MS/MS ion preparation methods, automated calibration blocks, and interactive graphics for data analysis.
Agilent 225-MS specifications
| Mass range | 10 to 650 Da |
|---|---|
| Resolution | Unit mass, measured as 10% valley |
| Scan rate | 5600 Da/s |
| Selected Ion Storage (SIS) | Stores up to five ranges of ions |
| Filament assembly | Dual filament |
| Power Requirements MS (120V) | 120 V ac + 10%, 60 Hz + 2%, 20 A, 2.4 kW |
| Power Requirements GC (120V) | 120 V ac + 10%, 60 Hz + 2%, 20 A, 2.4 kW |
| Dimensions MS (including foreline pump) | 24 cm (w) x 45 cm (h) x 68 cm (d) |
Source: Agilent 225-MS Ion Trap Mass Spectrometer Specifications
All Agilent 225-MS documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Mounting, wiring and first power-up. Read it before the hardware goes in.
How to use the product for one specific task, with worked examples.
Questions answered in these manuals
What is the mass range of the 225-MS?
The mass range is from 10 to 650 Da.
From: Agilent 225-MS Ion Trap Mass Spectrometer Specifications
What optional MS features are available for the 225-MS?
Optional features include Positive Chemical Ionization (PCI), SilChrom electrodes, and various software options like EnviroPro and ToxPro.
From: Agilent 225-MS Ion Trap Mass Spectrometer Specifications
What is the main advantage of the Varian 225-MS vacuum system?
It is a self-contained module that eliminates the need for a separate, standalone foreline pump and the associated hose, significantly reducing space requirements.
Does the Varian 225-MS require oil changes for the vacuum pump?
No, the vacuum module does not require oil changes or oil disposal during its lifetime.
What phthalate esters are regulated in toys?
The six regulated phthalate esters are dibutyl phthalate (DBP), benzyl butyl phthalate (BBP), diethylhexyl phthalate (DEHP), di-n-octyl phthalate (DNOP), diisononyl phthalate (DINP), and diisodecyl phthalate (DIDP).
From: Varian 225-MS Ion Trap Mass Spectrometer Application Note SI-02388
Can plastic toy samples be analyzed without sample preparation?
Yes, using low-pressure chemical ionization combined with MS/MS and the ChromatoProbe sample introduction device allows for direct analysis of plastic samples.
From: Varian 225-MS Ion Trap Mass Spectrometer Application Note SI-02388