Agilent 225-MS Manuals

ManualLib has 6 documents for the Agilent 225-MS: 5 user manuals, 1 installation guide. Every file can be read online or downloaded as a PDF for free.

User Manual 5Installation Guide 1

Key facts

Brand
Agilent
Model
225-MS
Industry
Industrial
Documents
6
Languages
EN
Last added
2012-07-04

Start here

Agilent Technologies 210-MS 220-MS 225-MS GC/MS Ion Trap Mass Spectrometer MS Workstation Version 6 Software Operation Manual

Agilent Technologies 210-MS 220-MS 225-MS GC/MS Ion Trap Mass Spectrometer MS Workstation Version 6 Software Operation Manual

User Manual 459 pages · 7.7 MB · EN

This document is the User's Guide and Reference Manual for the MS Workstation Version 6 software. It covers system configuration, instrument control, method creation and editing, data acquisition, calibration procedures, and report generation.

The manual details operations for controlling various mass spectrometers (210-MS, 220-MS, 225-MS) and gas chromatographs (431-GC, 450-GC). It includes instructions on using the MS/MS ion preparation methods, automated calibration blocks, and interactive graphics for data analysis.

Read online

Agilent 225-MS specifications

Mass range10 to 650 Da
ResolutionUnit mass, measured as 10% valley
Scan rate5600 Da/s
Selected Ion Storage (SIS)Stores up to five ranges of ions
Filament assemblyDual filament
Power Requirements MS (120V)120 V ac + 10%, 60 Hz + 2%, 20 A, 2.4 kW
Power Requirements GC (120V)120 V ac + 10%, 60 Hz + 2%, 20 A, 2.4 kW
Dimensions MS (including foreline pump)24 cm (w) x 45 cm (h) x 68 cm (d)

Source: Agilent 225-MS Ion Trap Mass Spectrometer Specifications

All Agilent 225-MS documents by type

Installation Guide 1

Mounting, wiring and first power-up. Read it before the hardware goes in.

Application Note 1

How to use the product for one specific task, with worked examples.

Questions answered in these manuals

What is the mass range of the 225-MS?

The mass range is from 10 to 650 Da.

From: Agilent 225-MS Ion Trap Mass Spectrometer Specifications

What optional MS features are available for the 225-MS?

Optional features include Positive Chemical Ionization (PCI), SilChrom electrodes, and various software options like EnviroPro and ToxPro.

From: Agilent 225-MS Ion Trap Mass Spectrometer Specifications

What is the main advantage of the Varian 225-MS vacuum system?

It is a self-contained module that eliminates the need for a separate, standalone foreline pump and the associated hose, significantly reducing space requirements.

From: Varian 225-MS Benchtop GC/MS System Product Leaflet

Does the Varian 225-MS require oil changes for the vacuum pump?

No, the vacuum module does not require oil changes or oil disposal during its lifetime.

From: Varian 225-MS Benchtop GC/MS System Product Leaflet

What phthalate esters are regulated in toys?

The six regulated phthalate esters are dibutyl phthalate (DBP), benzyl butyl phthalate (BBP), diethylhexyl phthalate (DEHP), di-n-octyl phthalate (DNOP), diisononyl phthalate (DINP), and diisodecyl phthalate (DIDP).

From: Varian 225-MS Ion Trap Mass Spectrometer Application Note SI-02388

Can plastic toy samples be analyzed without sample preparation?

Yes, using low-pressure chemical ionization combined with MS/MS and the ChromatoProbe sample introduction device allows for direct analysis of plastic samples.

From: Varian 225-MS Ion Trap Mass Spectrometer Application Note SI-02388