Texas Instruments UCC2808A Manuals

ManualLib has 3 documents for the Texas Instruments UCC2808A (Other Electronics): 2 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 2

Key facts

Model
UCC2808A
Documents
3
Languages
EN
Last added
2012-08-03

Start here

ManualTEXAS INSTRUEMNTS UCC2808A-1Q1 UCC2808A-2Q1 handbook

TEXAS INSTRUEMNTS UCC2808A-1Q1 UCC2808A-2Q1 handbook

This document introduces the features of the UCC2808A product, including ESD protection, dual output drive stage configuration, current sense discharge transistor, typical starting current, typical running current, operating frequency, internal soft start, error amplifier, VDD clamping, output drive stage, etc.

Read online

Texas Instruments UCC2808A specifications

Oscillator frequency175 kHz (min) – 213 kHz (max)
Peak source current per output500 mA
Peak sink current per output1 A
Output low‑level current100 mA
Over‑current threshold0.65 V (min) – 0.85 V (max)

Source: Texas Instruments UCC2808A-1Q1 Datasheet

All Texas Instruments UCC2808A documents by type

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

How many external components are needed to program the oscillator?

Only two external components – a resistor and a capacitor – are required to set the oscillator frequency.

From: Texas Instruments UCC2808A-1Q1 Datasheet

What does the internal discharge transistor on the CS pin do?

It discharges the filter capacitor on the CS pin each clock cycle, improving dynamic performance.

From: Texas Instruments UCC2808A-1Q1 Datasheet

What is the typical dead time between the two output stages?

The dead time is typically 60 ns to 200 ns, depending on the timing resistor and capacitor values.

From: TEXAS INSTRUMENTS UCC2808A-A handbook

What is the recommended supply current for the device?

The supply current (IDD) is limited to ≤ 10 mA.

From: TEXAS INSTRUMENTS UCC2808A-A handbook