Analog Devices ADR318 Manuals

ManualLib has 2 documents for the Analog Devices ADR318: 1 user manual, 1 datasheet. Every file can be read online or downloaded as a PDF for free.

User Manual 1Datasheet 1

Key facts

Model
ADR318
Industry
Industrial
Documents
2
Languages
EN
Last added
2012-08-03

Start here

ANALOG DEVICES ADR318: Precision Low Drift SOT-23 Voltage Reference with Shutdown Data Sheet (Rev A 2006-10-01-) handbook

ANALOG DEVICES ADR318: Precision Low Drift SOT-23 Voltage Reference with Shutdown Data Sheet (Rev A 2006-10-01-) handbook

Datasheet 12 pages · 477 KB · EN

The ADR318 is a precision 1.8 V band gap voltage reference designed for high accuracy, stability, and low power consumption. It features a wide operating range, low power consumption, and an additional shutdown capability, making it ideal for battery-powered applications. The device supports full Kelvin operation via a VOUT (SENSE) pin and is specified over an industrial temperature range of 0°C to 70°C in a tiny 5-lead SOT-23 package.

Read online

Analog Devices ADR318 specifications

Initial Accuracy±5 mV maximum
Initial Accuracy Error±0.27% maximum
Temperature Coefficient25 ppm/°C maximum
Load Regulation100 ppm/mA
Line Regulation25 ppm/V
Minimum Supply Voltage Headroom0.6 V
Quiescent Current120 μA maximum
Shutdown Supply Current3 μA maximum
Output Current5 mA
Operating Temperature Range0°C to 70°C
Package Type5-Lead SOT-23

Source: ANALOG DEVICES ADR318: Precision Low Drift SOT-23 Voltage Reference with Shutdown Data Sheet (Rev A 2006-10-01-) handbook

All Analog Devices ADR318 documents by type

Questions answered in these manuals

What is the initial accuracy of the ADR318?

The initial accuracy is ±5 mV maximum, which corresponds to an initial accuracy error of ±0.27% maximum.

From: ANALOG DEVICES ADR318: Precision Low Drift SOT-23 Voltage Reference with Shutdown Data Sheet (Rev A 2006-10-01-) handbook

What is the shutdown supply current?

The shutdown supply current is less than 3 μA maximum.

From: ANALOG DEVICES ADR318: Precision Low Drift SOT-23 Voltage Reference with Shutdown Data Sheet (Rev A 2006-10-01-) handbook

What is the initial accuracy of the ADR318?

The initial accuracy error is a maximum of +0.27%.

From: ANALOG DEVICES Precision Low Drift SOT-23 Voltage Reference with Shutdown ADR318* Manual

What is the minimum supply headroom required?

The device requires a minimum supply voltage of 600 mV above the output voltage.

From: ANALOG DEVICES Precision Low Drift SOT-23 Voltage Reference with Shutdown ADR318* Manual