ANALOG DEVICES ADR318: Precision Low Drift SOT-23 Voltage Reference with Shutdown Data Sheet (Rev A 2006-10-01-) handbook


ANALOG DEVICES ADR318: Precision Low Drift SOT-23 Voltage Reference with Shutdown Data Sheet (Rev A 2006-10-01-) handbook - cover page
Brand
Analog Devices
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
12
File format
PDF
File size
477 KB
Published
03 August, 2012
Updated
29 September, 2023
Models
SOT-23, ADR318
MD5 checksum
DDD9439DE57E077F747E5DC02C31F9A7

About this manual

The ADR318 is a precision 1.8 V band gap voltage reference designed for high accuracy, stability, and low power consumption. It features a wide operating range, low power consumption, and an additional shutdown capability, making it ideal for battery-powered applications. The device supports full Kelvin operation via a VOUT (SENSE) pin and is specified over an industrial temperature range of 0°C to 70°C in a tiny 5-lead SOT-23 package.

What's inside

  • Features
  • Applications
  • Specifications
  • Electrical Characteristics
  • Absolute Maximum Ratings
  • Thermal Resistance
  • Theory of Operation
  • Shutdown Mode Operation
  • Outline Dimensions
  • Ordering Guide

Specifications

Initial Accuracy±5 mV maximum
Initial Accuracy Error±0.27% maximum
Temperature Coefficient25 ppm/°C maximum
Load Regulation100 ppm/mA
Line Regulation25 ppm/V
Minimum Supply Voltage Headroom0.6 V
Quiescent Current120 μA maximum
Shutdown Supply Current3 μA maximum
Output Current5 mA
Operating Temperature Range0°C to 70°C
Package Type5-Lead SOT-23

Frequently asked questions

What is the initial accuracy of the ADR318?

The initial accuracy is ±5 mV maximum, which corresponds to an initial accuracy error of ±0.27% maximum.

What is the shutdown supply current?

The shutdown supply current is less than 3 μA maximum.

What is the minimum supply voltage headroom required?

The device requires a minimum supply headroom of 0.6 V above the output voltage.

What is the operating temperature range?

The ADR318 is specified over the industrial operating range of 0°C to 70°C.