Agilent 6890 GC Manuals

ManualLib has 21 documents for the Agilent 6890 GC: 2 product leaflets, 3 application notes, 1 other, 8 installation guides, 2 user manuals. Every file can be read online or downloaded as a PDF for free.

Product Leaflet 2Application Note 3Other 1Installation Guide 8User Manual 2

Key facts

Brand
Agilent
Model
6890 GC
Documents
21
Languages
EN
Last added
2012-07-05

Start here

Agilent G2333B G2334B Flame Photometric Detectors for Agilent 6890 GC Installation Operation

Agilent G2333B G2334B Flame Photometric Detectors for Agilent 6890 GC Installation Operation

User Manual 96 pages · 4.4 MB · EN

The document serves as a comprehensive guide for installing and operating the Agilent G2333B (single-wavelength) and G2334B (dual-wavelength) Flame Photometric Detectors (FPD). It details the contents of installation kits, required tools, and step-by-step procedures for preparing the Gas Chromatograph (GC), removing covers, installing flow modules and detector bodies, updating firmware, and reassembling the system. The manual distinguishes between the single-wavelength model requiring filter changes and the dual-wavelength model capable of simultaneous sulfur and phosphorus detection.

Read online

Agilent 6890 GC specifications

Minimum controlled inlet pressure1.0 psig
Maximum allowable flow to MSD10-* torr ion gauge reading
Recommended backflush durationat least 5 void times

Source: Agilent 6890 GC Simplified Backflush Application Note

All Agilent 6890 GC documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the total concentration of PCB standards used in the sensitivity test?

The test used a mixture of commercial PCB standards at a total concentration of 500 ppm.

From: Agilent PBDE Analysis by GC-ICP-MS Technical Feature Manual

What is the concentration range of the calibration curve for PBDE-183?

The calibration graph for PBDE-183 covers a range from 10 ppb to 1 ppm.

From: Agilent PBDE Analysis by GC-ICP-MS Technical Feature Manual

What is the recommended duration for backflushing?

The document recommends backflushing for at least 5 void times to ensure all components are removed from the column.

From: Agilent 6890 GC Simplified Backflush Application Note

Which pump type is required for backflushing?

Backflushing should only be done with turbopump systems due to the limited pumping capacity of diffusion pumps.

From: Agilent 6890 GC Simplified Backflush Application Note

What hazardous substances are restricted by RoHS/ELV regulations?

The regulated substances include cadmium (Cd), mercury (Hg), lead (Pb), hexavalent chromium (Cr(VI)), and brominated flame retardants (BFRs).

From: Agilent Technologies WEEE/RoHS/ELV Compliance Brochure

What are the EU limits for Lead (Pb)?

The EU limit for Lead in finished materials is 1000mg/kg (0.1%).

From: Agilent Technologies WEEE/RoHS/ELV Compliance Brochure