Key facts
- Brand
- Agilent
- Model
- 6890 GC
- Documents
- 21
- Languages
- EN
- Last added
- 2012-07-05
Start here

Agilent G2333B G2334B Flame Photometric Detectors for Agilent 6890 GC Installation Operation
The document serves as a comprehensive guide for installing and operating the Agilent G2333B (single-wavelength) and G2334B (dual-wavelength) Flame Photometric Detectors (FPD). It details the contents of installation kits, required tools, and step-by-step procedures for preparing the Gas Chromatograph (GC), removing covers, installing flow modules and detector bodies, updating firmware, and reassembling the system. The manual distinguishes between the single-wavelength model requiring filter changes and the dual-wavelength model capable of simultaneous sulfur and phosphorus detection.
Read onlineAgilent 6890 GC specifications
| Minimum controlled inlet pressure | 1.0 psig |
|---|---|
| Maximum allowable flow to MSD | 10-* torr ion gauge reading |
| Recommended backflush duration | at least 5 void times |
Source: Agilent 6890 GC Simplified Backflush Application Note
All Agilent 6890 GC documents by type
How to use the product for one specific task, with worked examples.
Mounting, wiring and first power-up. Read it before the hardware goes in.
- Agilent Heater Interface Cable for the 5973 MSD the 6890 GC - Installation Guide 12 p
- Agilent 6890 GC ECD Installation guide 29 p
- Agilent 6890 GC EPC Board Installation Guide G1557A 18 p
- Agilent 6890 Accessories-Installation Guides (G1544-90307 S/SL) 20 p
- Agilent 6890 Accessories-Installation Guides (G1532-90337 TCD) 28 p
- Agilent 7694 Headspace Sampler - Installing the Interface Kit for the 6890 GC guide 6 p
- Agilent G2747A Nickel Catalyst Kit Installation Guide for 6890 GC 20 p
- Agilent G2317A Pneumatics Control Module Installation Guide for the Agilent 6890 GC 20 p
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- Agilent The Benefits of Setting Up a UNITYe-Based Thermal Desorber Using an Agilent 6890 GC s Electronic Pneumatic Control Manual
- Agilent On-Column Capillary Inlet with EPC Installation Guide for 6890 GC
- Agilent G1585A Side Carrier for Manual Inlet Flow Module (6890 GC) Install Guide
- Agilent - Installing a nonEPC Purge Packed Inlet (6890 GC) Manual
- Agilent G2647A G2648A Flame Photometric Detector Update Kits For Agilent 6850 6890 GCs Update Operation Maintenance
Questions answered in these manuals
What is the total concentration of PCB standards used in the sensitivity test?
The test used a mixture of commercial PCB standards at a total concentration of 500 ppm.
From: Agilent PBDE Analysis by GC-ICP-MS Technical Feature Manual
What is the concentration range of the calibration curve for PBDE-183?
The calibration graph for PBDE-183 covers a range from 10 ppb to 1 ppm.
From: Agilent PBDE Analysis by GC-ICP-MS Technical Feature Manual
What is the recommended duration for backflushing?
The document recommends backflushing for at least 5 void times to ensure all components are removed from the column.
Which pump type is required for backflushing?
Backflushing should only be done with turbopump systems due to the limited pumping capacity of diffusion pumps.
What hazardous substances are restricted by RoHS/ELV regulations?
The regulated substances include cadmium (Cd), mercury (Hg), lead (Pb), hexavalent chromium (Cr(VI)), and brominated flame retardants (BFRs).
From: Agilent Technologies WEEE/RoHS/ELV Compliance Brochure
What are the EU limits for Lead (Pb)?
The EU limit for Lead in finished materials is 1000mg/kg (0.1%).
From: Agilent Technologies WEEE/RoHS/ELV Compliance Brochure