Agilent 7890A Manuals

ManualLib has 66 documents for the Agilent 7890A (Other): 5 service manuals, 32 application notes, 9 product leaflets, 2 datasheets, 2 others, 4 quick start guides, 7 user manuals, 2 installation guides. Every file can be read online or downloaded as a PDF for free.

Service Manual 5Application Note 32Product Leaflet 9Datasheet 2Other 2Quick Start Guide 4User Manual 7Installation Guide 2

Key facts

Brand
Agilent
Model
7890A
Category
Other
Industry
Industrial
Documents
66
Languages
ZH · JA · IT · DE · FR · EN · ES
Last added
2026-11-10

Start here

Agilent Technologies 7890A Gas Chromatograph Quick Reference Guide

Agilent Technologies 7890A Gas Chromatograph Quick Reference Guide

Quick Start Guide 34 pages · 683 KB · FR

This document serves as a succinct presentation of user documentation for the Agilent 7890A system. It acts as a quick reference for the instrument's keypad operations and outlines the essential steps required to install the Gas Chromatograph (CPG). Users are directed to the accompanying DVD for extended online help, safety regulations, maintenance manuals, and troubleshooting guides. This manual is written in French.

Read online

Agilent 7890A specifications

NPD output (typical)5.0 to 50.0 pA
FPD Lit offset (typical)2.0 pA
Internal log capacityUp to 250 entries per log

Source: Agilent 7890A Gas Chromatograph Troubleshooting Manual

All Agilent 7890A documents by type

Application Note 32

How to use the product for one specific task, with worked examples.

Datasheet 2

Ratings, dimensions and ordering codes, for selection and design work.

Installation Guide 2

Mounting, wiring and first power-up. Read it before the hardware goes in.

Questions answered in these manuals

How do I verify that the NPD rubidium bead is lit?

Look through the vent on the detector cover for an orange-red glow from the rubidium bead.

From: Agilent 7890A Gas Chromatograph Troubleshooting Manual

How do I verify that the FPD flame is lit?

Remove the rubber dropper from the detector exhaust and place a mirror or shiny object near the aluminum exhaust pipe; steady water condensation indicates the flame is lit.

From: Agilent 7890A Gas Chromatograph Troubleshooting Manual

Which vegetable oil feedstocks are suitable for these biodiesel analysis methods?

The methods apply to B100 biodiesel produced from vegetable oils such as rapeseed, soybean, sunflower, and palm.

From: Analysis of Glycerine and Glycerides in Biodiesel (B100) Using the ASTM D6584 and EN14105 Methods

Which biodiesel feedstocks are not suitable for these methods?

The methods are not suitable for B100 biodiesel produced from lauric acid sources such as coconut and palm kernel.

From: Analysis of Glycerine and Glycerides in Biodiesel (B100) Using the ASTM D6584 and EN14105 Methods

What is the maximum data acquisition speed of the FID detector?

The high-speed FID detector can operate at a maximum frequency of 500 Hz.

From: Agilent 7890A GC Capillary Flow Technology Brochure

How does Capillary Flow Technology improve column switching?

It allows for the exchange of columns between Gas Evolution Analysis (EGA) and Double Shot Analysis without venting the mass spectrometer.

From: Agilent Capillary Flow Technology Application for Pyrolysis GC/MS Analysis