Key facts
- Brand
- Analog Devices
- Model
- OP162
- Industry
- Industrial
- Documents
- 4
- Languages
- EN
- Last added
- 2012-08-08
Start here

Analog Devices OP162/OP262/OP462 Operational Amplifiers Datasheet
The document describes the OP162 (single), OP262 (dual), and OP462 (quad) rail-to-rail 15 MHz operational amplifiers. These devices feature low offset voltage, low noise, and single-supply operation ranging from +2.7 V to +12 V. They are designed for portable instrumentation, sampling ADC amplifiers, and wireless LANs, offering high slew rates and unity gain stability.
Read onlineAnalog Devices OP162 specifications
| Gain Bandwidth Product | 15 MHz |
|---|---|
| Supply Voltage Range | +2.7 V to +12 V |
| Slew Rate | 13 V/µs |
| Operating Temperature Range | -40°C to +125°C |
Source: Analog Devices OP162/OP262/OP462 Operational Amplifiers Datasheet
All Analog Devices OP162 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the maximum supply voltage for these amplifiers?
The maximum supply voltage is +6 V for absolute maximum ratings, though typical operation is specified up to +12 V.
From: Analog Devices OP162/OP262/OP462 Operational Amplifiers Datasheet
Are these amplifiers unity gain stable?
Yes, the OP162/OP262/OP462 amplifiers are unity gain stable.
From: Analog Devices OP162/OP262/OP462 Operational Amplifiers Datasheet
What supply voltage range do the OP162/OP262/OP462 amplifiers support?
They operate from a single supply as low as 2.7 V up to 12 V, or from dual supplies of ±6 V.
What is the maximum output current of these amplifiers?
The devices can source or sink up to 30 mA continuously, with a short‑circuit current rating of 80 mA.
What supply voltage range do the OP162/OP262/OP462 support?
They operate from a single supply as low as 2.7 V up to 12 V.
What is the maximum continuous output current for these amplifiers?
The devices can source or sink up to 30 mA continuously.