Agilent VF-5MS Manuals

ManualLib has 2 documents for the Agilent VF-5MS: 1 application note, 1 user manual. Every file can be read online or downloaded as a PDF for free.

Application Note 1User Manual 1

Key facts

Brand
Agilent
Model
VF-5MS
Industry
Industrial
Documents
2
Languages
EN
Last added
2012-06-11

Start here

Agilent J&W FactorFour VF-5ms GC Column Application Note

Agilent J&W FactorFour VF-5ms GC Column Application Note

Application Note 5 pages · 167 KB · EN

The document details an analytical method to analyze 16 polycyclic aromatic hydrocarbons (PAHs), 17 polychlorinated biphenyls (PCBs), and 24 organochlorine pesticides (OCPs) in a single run. This approach is designed to improve productivity for environmental samples by reducing analysis time compared to performing separate analyses for each compound group.

The method utilizes GC/MS with the Agilent J&W FactorFour VF-5ms column, achieving separation of 57 compounds within 32 minutes. The note discusses specific challenges in separating certain peak pairs that have identical masses or difficult resolution using mass spectrometry alone, providing strategies for confirmation via Selected Ion Monitoring (SIM).

Read online

Agilent VF-5MS specifications

ColumnVF-5ms, 10 mx 0.15 mm x 0.15 um
Part NumberCP9034
CartridgeBondElut C18, 200 mg
Carrier Gas0.5 mL/min Helium
Injector Temperature250 °C
DetectorTriple quadripole GC
Ion Source Temperature250 °C
Analysis Time12 minutes

Source: Agilent J&W FactorFour VF-5ms Column Application Note for Fast GC/MS/MS of Androgenic Anabolic Steroids

All Agilent VF-5MS documents by type

Questions answered in these manuals

How long does the multi-residue analysis of PAHs, PCBs, and OCPs take on this column?

The VF-5ms column delivers a multi-residue analysis of PAHs, PCBs, and OCPs in 32 minutes.

From: Agilent J&W FactorFour VF-5ms GC Column Application Note

What are the specified sample concentrations for PAHs, OCPs, and PCBs in this method?

The concentration of the PAHs was ten times higher than the concentration of PCBs and OCPs, with PAHs at 1 wg/mL and OCPs and PCBs at 0.1 yg/mL.

From: Agilent J&W FactorFour VF-5ms GC Column Application Note

How many anabolic steroids can this method screen?

The method is designed to screen 13 anabolic androgenic steroids.

From: Agilent J&W FactorFour VF-5ms Column Application Note for Fast GC/MS/MS of Androgenic Anabolic Steroids

What is the total analysis time for the method?

The analysis is completed within 12 minutes.

From: Agilent J&W FactorFour VF-5ms Column Application Note for Fast GC/MS/MS of Androgenic Anabolic Steroids