Key facts
- Brand
- Analog Devices
- Model
- AD10200
- Industry
- Industrial
- Documents
- 4
- Languages
- EN
- Last added
- 2022-09-28
Start here

Analog Devices AD10200 Dual Channel 12-Bit IF Sampling A/D Converter Datasheet
The AD10200 is a full channel ADC solution featuring two wide-dynamic range ADCs optimized for Direct-IF sampling. It includes an on-module transformer-coupled front-end and track-and-hold circuitry to achieve 12-bit performance at speeds up to 105 MSPS with excellent channel-to-channel matching.
The device operates from a single 5.0 V supply and is packaged in a 68-lead ceramic chip carrier. It supports industrial and military grade applications, operating over a temperature range of –50°C to +125°C.
Analog Devices AD10200 specifications
| Resolution | 12 Bits |
|---|---|
| Sample Rate (Max) | 105 MSPS |
| Channel-to-Channel Isolation | >80 dB |
| Operating Temperature | -50°C to +125°C |
| Package Type | 68-lead ceramic chip carrier |
Source: Analog Devices AD10200 Dual Channel 12-Bit IF Sampling A/D Converter Datasheet
All Analog Devices AD10200 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What are the applications for the AD10200?
It is designed for Radar IF Receivers, Phased Array Receivers, Communications Receivers, Secure Communications, GPS Antijamming Receivers, and Multichannel, Multimode Receivers.
From: Analog Devices AD10200 Dual Channel 12-Bit IF Sampling A/D Converter Datasheet
What is the input voltage range?
The analog input voltage range is 2.048 V p-p.
From: Analog Devices AD10200 Dual Channel 12-Bit IF Sampling A/D Converter Datasheet
What is the input VSWR range for the AD10200?
The input VSWR is guaranteed from 1.1:1 up to the Nyquist frequency.
What temperature range can the AD10200 operate in?
It is rated for operation from –55 °C to +125 °C.
What is the guaranteed minimum sample rate of the AD10200?
The AD10200 guarantees a minimum sample rate of 105 MSPS.
What are the operating temperature limits for the AD10200?
It operates from –55 °C up to +125 °C.