STMicroelectronics LIS302DL MEMS Motion Sensor Datasheet
The LIS302DL is an ultra-compact, low-power three-axis linear accelerometer manufactured by STMicroelectronics. It utilizes a dedicated silicon process for the sensing element and a CMOS process for the IC interface, allowing for precise matching of characteristics. The device supports dynamically selectable full scales of +2g and +8g and offers output data rates of 100 Hz or 400 Hz.
Read onlineSTMicroelectronics LIS302DL specifications
| Supply voltage | 2.16 V to 3.6 V |
|---|---|
| Power consumption | <1 mW |
| Full-scale range | +2g/+8g |
| Output data rate | 100 Hz or 400 Hz |
| Operating temperature | -40 °C to +85 °C |
| Package type | LGA 14 (TLGA) |
| Shock survivability | 10000g |
Source: STMicroelectronics LIS302DL MEMS Motion Sensor Datasheet
All STMicroelectronics LIS302DL documents by type
Ratings, dimensions and ordering codes, for selection and design work.
How to use the product for one specific task, with worked examples.
Questions answered in these manuals
What are the selectable full-scale ranges for the LIS302DL?
The device supports dynamically user selectable full scales of +2g and +8g.
From: STMicroelectronics LIS302DL MEMS Motion Sensor Datasheet
Does the LIS302DL include a self-test capability?
Yes, a self-test capability allows the user to check the functioning of the sensor.
From: STMicroelectronics LIS302DL MEMS Motion Sensor Datasheet
What is the LIS302DL?
It is an ultra compact low-power three axes linear accelerometer that includes a sensing element and an IC interface.
From: ST AN2335 handbook
Does the LIS302DL have a self-test capability?
Yes, the device has a self-test capability that allows the user to check the correct operation of the system.
From: ST AN2335 handbook
What are the click detection thresholds?
The threshold value is expressed over 4 bits as an unsigned number, ranging from 0.5g to 7.5g with increments of 0.5g.
What is the maximum time interval for a single click?
The TimeLimit register defines the maximum time interval between the start of detection and when acceleration goes back below the threshold, ranging from 0 to 127.5 msec.