STMicroelectronics AN2579 LIS302DL Application Note

This application note provides application information for the LIS302DL low-voltage 3-axis digital output linear MEMS accelerometer housed in an LGA package. The LIS302DL is an ultra-compact, low-power 3-axis linear accelerometer that includes a sensing element and an IC interface capable taking information from the sensing element and providing the measured acceleration data to external applications via an I2C/SPI serial interface.


STMicroelectronics AN2579 LIS302DL Application Note - cover page
Brand
STMicroelectronics
Category
Other Electronics
Document type
Application Note
Language
English
Pages
15
File format
PDF
File size
812 KB
Published
06 August, 2012
Updated
01 October, 2023
MD5 checksum
B35CE9CF44A4DD2ADC49B8A6A41DB1EA

About this manual

The document provides application information for the LIS302DL low-voltage 3-axis linear accelerometer, which is housed in an LGA package. It details how to translate finger taps into actions using single and double click recognition functions.

The note explains the theory of operation for detecting single clicks (interrupts generated when acceleration exceeds a threshold) and double clicks (two rapid stimuli within specific time windows). It includes register descriptions for configuring thresholds, timing limits, latency, and window settings to customize these detection events.

What's inside

  • Theory of operation
  • Single click recognition
  • Double click recognition
  • Register description
  • CLICK_CFG register
  • CLICK_SRC register
  • Threshold registers (THSx, THSy, THSz)
  • Timing registers (TimeLimit, Latency, Window)

Specifications

Product Type3-axis digital MEMS accelerometer
Package Typeplastic SMD package / LGA package
Operating Temperature Range-40 °C to +85 °C
Output Data Rate100 Hz or 400 Hz
Full Scale Selection+2g and +8g

Frequently asked questions

What are the click detection thresholds?

The threshold value is expressed over 4 bits as an unsigned number, ranging from 0.5g to 7.5g with increments of 0.5g.

What is the maximum time interval for a single click?

The TimeLimit register defines the maximum time interval between the start of detection and when acceleration goes back below the threshold, ranging from 0 to 127.5 msec.

How is double click latency configured?

The Latency register defines the time interval after the first click where detection is disabled, ranging from 0 to 255 msec.