STMicroelectronics BTA06 and BTB06 Series 6A Triacs Datasheet
This datasheet describes the BTA06 and BTB06 series of 6A triacs, which are suitable for general-purpose AC switching applications such as static relays, heating regulation, and phase control. The series includes snubberless and logic level versions specifically recommended for inductive loads, as well as standard versions for four-quadrant operation. Devices are available in both through-hole and surface-mount TO-220AB packages, with options for insulated and non-insulated tabs.
Read onlineSTMicroelectronics BTB06 specifications
| RMS on-state current | 6 A |
|---|---|
| Peak off-state voltage | 600 and 800 V |
| Minimum gate trigger current | 5 to 50 mA |
| Package type | TO-220AB |
| Voltage insulated tab rating | 2500 V |
| Operating junction temperature range | - 40 to + 125 °C |
Source: STMicroelectronics BTA06 and BTB06 Series 6A Triacs Datasheet
All STMicroelectronics BTB06 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What are the main applications for these triacs?
They are suitable for static relays, heating regulation, induction motor starting circuits, light dimmers, and motor speed controllers.
From: STMicroelectronics BTA06 and BTB06 Series 6A Triacs Datasheet
What is the maximum power dissipation for the insulated package?
The thermal resistance from junction to ambient for the TO-220AB insulated package is 60 °C/W.
From: STMicroelectronics BTA06 and BTB06 Series 6A Triacs Datasheet
Which version is recommended for inductive loads?
The snubberless and logic level versions (BTA/BTB...W) are specially recommended for use on inductive loads.
What is the voltage rating of the insulated tab?
The internal ceramic pad provides a voltage insulated tab rated at 2500V RMS, complying with UL standards.
What is the maximum RMS on-state current for the BTA model?
The maximum RMS on-state current for the BTA model at a junction temperature of 85°C is 6 A.
From: SGS-THOMSON BTA06/BTB06 Sensitive Gate Triacs Datasheet
What are the operating junction temperature limits?
The device operates within a junction temperature range of -40 to +110 °C.
From: SGS-THOMSON BTA06/BTB06 Sensitive Gate Triacs Datasheet