Key facts
- Brand
- STMicroelectronics
- Model
- BTB06
- Industry
- Industrial
- Documents
- 3
- Languages
- EN
- Last added
- 2012-08-10
Start here
ST BTA06 BTB06 Series 6A TRIACS handbook
This datasheet provides all the information about BTA06 and BTB06 series 6A triacs including technical specifications, order codes, packages etc.
Read onlineSTMicroelectronics BTB06 specifications
| Voltage rating | 600 and 800 V |
|---|---|
| Gate trigger current (logic level) | 5 to 50 mA |
| Package type | TO-220AB Insulated / TO-220AB |
| Storage junction temperature range | - 40 to + 150 °C |
All STMicroelectronics BTB06 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
Which version is recommended for inductive loads?
The snubberless and logic level versions (BTA/BTB...W) are specially recommended for use on inductive loads.
What is the voltage rating of the insulated tab?
The internal ceramic pad provides a voltage insulated tab rated at 2500V RMS, complying with UL standards.
What is the maximum RMS on-state current for the BTA model?
The maximum RMS on-state current for the BTA model at a junction temperature of 85°C is 6 A.
From: SGS-THOMSON BTA06/BTB06 Sensitive Gate Triacs Datasheet
What are the operating junction temperature limits?
The device operates within a junction temperature range of -40 to +110 °C.
From: SGS-THOMSON BTA06/BTB06 Sensitive Gate Triacs Datasheet